SIQENS Ecoport 800
Operation
Page 31 of 49
5.1.2.
Only manually
In manual mode, the operation of the Ecoport is started and stopped via the control panel. No
further configuration is necessary.
A manual start of the Ecoport is possible at any time. Even if the operating mode "battery voltage"
or "external input" is selected.
Select: Manually only
Select the option " Manually only"
under "Settings" in the menu item
"Startup" and confirm your
selection.
The Ecoport can be started as
desired via the "Home" menu.
5.1.3.
External input
The Ecoport can be started using the signal connector.
A typical application is, for example, a user-defined hard-wired switch and automatic control by an
external battery management system (BMS).
Functionality
The Ecoport is started by short-circuiting pin 1 and pin 2. This
can be controlled via an external switch.
When the switch is opened, the Ecoport stops producing
power and returns to stand-by.
Select: External input
Under "Settings" in the "Startup"
menu, select the "External input"
option and confirm your selection.