Storage Procedure
After use, remove the pump drain plug and drain the pump
chamber. Remove the filler cap and flush the pump chamber
with clean fresh water. Allow the water to drain from the pump
chamber and then reinstall the filler cap and drain plug.
Servicing Pump
The maintenance schedule applies to normal operating conditions. If operating the Pump under severe
conditions, such as sustained high load or high temperature operation or unusually wet or dusty conditions
increase maintenance to each time Pump is used.
Safety Precautions When Servicing Your Pump
Make sure the engine is off before you begin any maintenance or repairs to eliminate potential hazards such as:
• Carbon monoxide poisoning from engine exhaust
• Burns from hot parts
• Injury from moving parts
Read instructions before you begin and make sure you have the tools and skills required to perform the tasks.
To reduce the possibility of fire or explosion use caution when working around gasoline. Use only nonflammable
solvent and do not use gasoline to clean parts. Keep flames and sparks away at all times.
Maintenance Schedule
Item / Maintenance
Required
Each use
1st month
– 10 hours
3 months –
25 hours
6 months –
50 hours
1 year –
100 hours
2 years –
300 hours
Engine Oil
Check
Level
Change
Air Filter (Replace if
damaged)
Check
Clean
Nuts, Bolts, Fasteners
Check
Spark Plug
Check
Replace
Engine Cooling Fins
Clean
Fuel Tank
Clean
Fuel Filter
Clean
Fuel Tubes
Check
Oil Tubes
Check
12