6. SYSTEM OPERATION RULES (continued)
CAUTION:
Do not operate UP system without cooling of Tool by compressed air.
The exceptions could be the verification of the condition of system (3-5 seconds)
and/or short demonstration (no more than 1 minute). Make sure that the air for
cooling of Tool is clean and not warm/hot.
6.3.9 Press the Tool against the treated part with a force of 30–50 N to start the
Ultrasonic Peening process.
Status
indicator illuminates continuously
during the treatment and the
Select
/
Set
timer starts the countdown.
When the timer reaches zero, the Tool automatically switches off. The
treatment also could be interrupted at any time and than continued again
until the end of pre-set time.
6.3.10 If necessary, the operation may be stopped and the operation time may
be re-set (
Select
/
Set
indicator blinks). The level of ultrasonic energy may
be re-set also by
Set Range
button.
6.3.11 The system is designed to protect the Tool from overheating. In case of
overheat of UP system, the ultrasound is switching of automatically, and
letters
OH
(overheat) illuminates on the indicator instead of time. Promptly
suspend operation for no less than half an hour. The
Power
button should
be turned to the OFF position. The treatment may be continued after the
Tool cooled down (not less than in half an hour).
6.4. MAINTENANCE AND REPAIR
While on warranty, technical maintenance and repair of the System should be done
by Manufacturer or its representative only. Extended warranty could be arranged for
different terms.