![Sino Wealth SH61F83 Manual Download Page 37](http://html1.mh-extra.com/html/sino-wealth/sh61f83/sh61f83_manual_1283060037.webp)
SH61F83
37
Following figures show how Time Capture function works on TC0 input signal with different H/W setting condition
8 bit Free Run
Counter
TC0 Input
TCAP0R Register
D0
D1
D3
D4
D5
D6
D7
D8
D9
DA
TCAP0F Register
TC0R_FULL
TC0F_FULL
ETC0 IRQ
(F/W read TCAP0R & TCAP0F register)
D3
XX
XX
DF
EC
D9
E6
(F/W read TCAP0R & TCAP0F register)
TC_CLREN = 0, EA = 1, ETC0 = 1,
TC0F_INT = 0, TC0R_INT = 1
DB
DC
DD
DE
DF
E0
E1
E3
E4
E5
E6
E7
E8
E9
EA
EB
EC
ED
EE
EF
CF
Figure 9-2. Timing Diagram of TC0 #1
8 bit Free Run
Counter
TC0 Input
TCAP0R Register
TC_CLREN = 0, EA = 1, ETC0 = 1,
TC0F_INT = 1, TC0R_INT = 1
TCAP0F Register
TC0R_FULL
TC0F_FULL
ETC0 IRQ
(F/W read TCAP0R)
D3
XX
XX
DF
EC
D9
E6
(F/W read TCAP0F)
D0
D1
D3
D4
D5
D6
D7
D8
D9
DA
DB
DC DD
DE
DF
E0
E1
E3
E4
E5
E6
E7
E8
E9
EA
EB
EC
ED
EE
EF
CF
Figure 9-3. Timing Diagram of TC0 #2