① This Connection requires 5 wires: L1, L2, L3, Neutral and Ground.
② This
connection requires 4 wires: L1, L2, Neutral and Ground.
③ This Connection requires 3 wires: L1, Neutral
and Ground.
Specifications (Electric Ovens)
/ Spécifications / Especificaciones
Model
/
Modèle /
Modele
H x W x D*
Clearance to Combustibles
/
Distance aux combustibles /
Distancia hasta Combustibles
Weight
/ Poids / Peso
Class
/
Classe /
Clase
Actual
/
Réel /
Real
Crated
/
Crated /
Crated
77.5
LRO-1
__
105 x 55 x 88"
[2654x1397x2235mm]
Sides 0, Back 0
/
Flanc 0, Derrière 0 /
Costado 0, Parte Posterior 0
2500 lb
[1135 kg]
2900 lb
[1315 kg]
LRO-2
__
105 x 72 x 108"
[2654x1829x2743mm]
3380 lb
[1530 kg]
4380 lb
[1990 kg]
Electric Requirements
/ ExigenceÉlectriques / Requisitos Eléctricos
Model
/
Modèle /
Modele
Voltage
/ Tension / Voltaje
kW
Min Circuit
Amps
/
Circuit Min /
Circuito Mín
Max Breaker
Amps
/ Disjoncteur de Max
/ Interruptor de Máx
LRO-1E5
120V/208VAC, 3ph, 60 Hz
①
41.5
145
175
Optional
Voltage
120V/240VAC, 3ph, 60 Hz
①
41.5
125
150
120VAC, 1ph, 60Hz
③
/480VAC, 3ph, 60Hz
②
(Not Available in Canada)
40
15/85
20/100
480 VAC, 3ph, 60 Hz
②
40
85
100
LRO-2E5
120V/208VAC, 3ph, 60 Hz
①
51.6
180
200
Optional
Voltage
120V/240VAC, 3ph, 60 Hz
①
55
165
200
120VAC, 1ph, 60 Hz
③
/480VAC, 3ph, 60 HZ
②
(Not Available in Canada)
55
15/85
20/100
480 VAC, 3ph, 60 Hz
②
55
85
100
Model
CFM M3/Min
ǂ
Pressure Drop
Eyebrow
Hood Type
Input Pressure
/ Pression d'Entrée /
Presión de Entrada
LRO-1__
530 15
1” wc
[250 Pa]
Type II or
Type I as
required.
ǂǂ
40 psi
[275 kPa]
Min;
100 psi
[700 kPa]
Max
LRO-2
__
800 23
Water Condition
/ Eau Condition / Agua Conditción
Alkalinity < 22 ppm
Magnesium < 0.65 ppm
Aluminum < 17 ppm
pH = 8.5
Calcium < 3.3 ppm
Sodium < 8.5 ppm
Free Chlorine Radical < 0.6 ppm
Total Hardness < 11.9 ppm
*
Clearance, tilt up
/ Dégagement d'incliner / Espacio libre para inclinara
= 112"
[2845mm]
**
Non-combustible floors supported by non-combustible structure
/ Planchers combustibles non pris en charge par la
structure combustible non / Pisos no combustibles soportados por la estructura no combustible
ǂ
External roof-top fan required
/ Externe sur le toit ventilateur requis / Externa en la azotea requiere ventilador
ǂǂ
Per local Codes
/
Par codes locaux
/
Por códigos locales
Summary of Contents for LBC LRO-1E5
Page 45: ...Copyright 2016 2019 LBC Bakery Equipment Inc Marysville WA USA P a g e 45 Schematics ...
Page 46: ...Copyright 2016 2019 LBC Bakery Equipment Inc Marysville WA USA P a g e 46 ...
Page 47: ...Copyright 2016 2019 LBC Bakery Equipment Inc Marysville WA USA P a g e 47 ...
Page 48: ...Copyright 2016 2019 LBC Bakery Equipment Inc Marysville WA USA P a g e 48 ...
Page 49: ...Copyright 2016 2019 LBC Bakery Equipment Inc Marysville WA USA P a g e 49 ...
Page 50: ...Copyright 2016 2019 LBC Bakery Equipment Inc Marysville WA USA P a g e 50 ...