29
SM01 using this signal and measured with the Tektronix VM700 is shown in
Appendix A.
Bounce
The bounce test signal switches between black and white test signals at
field frequency (50 or 60Hz). It is used to measure field time distortion or
detect clamping issues.
Sweep
Sweep is a swept frequency waveform used for testing the system
frequency response.
For PAL/NTSC the frequency range is 0.25MHz to 5.75MHz for luma and
0.125MHz to 2.75MHz for chroma.
For 960H the frequency range is 0.25MHz to 7.75MHz for luma and
0.125MHz to 2.75MHz for chroma.
Figure 16 Sweep Waveform
525 Line Sweep
0
100
200
300
400
500
600
700
800
900
0
100
200
300
400
500
600
700
800
Y Pixel No.
1
0
b
it
v
a
lu
e
0
100
200
300
400
500
600
700
800
900
0
50
100
150
200
250
300
350
400
Cb/Cr Pixel No.
Y Value (Dec)
Cb Value (Dec)
Cr Value (Dec)
Summary of Contents for SM01
Page 12: ...12 Menu control The complete menu structure is shown in Figure 4 Figure 4 SM01 Menu structure ...
Page 44: ...44 Figure 30 PAL vertical timing composite output ...
Page 45: ...45 Figure 31 NTSC Horizontal timing composite output ...
Page 47: ...47 Figure 33 NTSC 75 colour bar composite output ...
Page 48: ...48 Figure 34 NTSC 75 colour bars vectors ...
Page 49: ...49 Figure 35 PAL 75 colour bars composite output ...
Page 53: ...53 Figure 39 NTSC Differential gain phase measurement ...
Page 54: ...54 Figure 40 NTSC noise measurement Pedestal waveform ...
Page 55: ...55 Figure 41 Luma frequency response CCIR18 test signal ...
Page 58: ...58 Figure 45 SDI output 625 line eye pattern ...
Page 59: ...59 Figure 46 SDI output 625 line jitter measurement ...
Page 61: ...61 Figure 48 AC DC converter specification Page 2 ...
Page 62: ...62 Figure 49 AC DC converter specification Page 3 ...