20
ENGLISH
Bad functioning
Is the air
fi
lter clogged?
Clean the air
fi
lter as
instructed
Is the intake duct or
discharge duct ob-
structed?
Remove the obstruction
from the discharge duct
or intake duct.
No air intake
Is the
fi
lter clogged?
Wash the
fi
lter
Loud noise when run-
ning
Is the machine put in
the plat place?
Put the machine on the
plat ground
Is the
fi
lter clogged?
Wash the
fi
lter
E2
Humidity sensor prob-
lem
Change a sensor
LO
Environmental humidity
is below 20%
The dehumidi
fi
er shuts
down for self- protec-
tion
HI
Environmental humidity
is above 90%
CL
Low temperature
protection, the envi-
ronmental tempera-
ture<5
℃
CH
High temperature
protection, the envi-
ronmental tempera-
ture>35
℃
PRODUCT REPAIR FOR APLLIANCES CONTAINING R290
Warnings
•
Do not exceed impedance greeter than 0.236ohm in supply the appli-
ance is connected to. Failure to comply may lead the supply authority
to impose restrictions to connection. Please consult your energy supply
authority if the use of equipment exceeds 0.236 ohm.
•
All operators or refrigeration circuit maintenance personnel should obtain
a valid certi
fi
cate issued by an industry-approved assessment agency to