28
ENGLISH
ly and all isolation valves on the equipment are closed off.
k) Recovered refrigerant shall not be charged into another refrigerating sys-
tem unless it has been cleaned and checked.
18. Labelling
Equipment shall be labelled stating that it has been decommissioned and emp-
tied of refrigerant. The label shall be dated and signed. For appliances con-
taining
fl
ammable refrigerants, ensure that there are labels on the equipment
stating the equipment contains
fl
ammable refrigerant.
19. Recycling
When removing refrigerant from a system, either for servicing or decommis-
sioning, it is recommended good practice that all refrigerants are removed
safely.
When transferring refrigerant into cylinders, ensure that only appropriate re-
frigerant recovery cylinders are employed. Ensure that the correct number
of cylinders for holding the total system charge is available. All cylinders to
be used are designated for the recovered refrigerant and labelled for that re-
frigerant (i.e. special cylinders for the recovery of refrigerant). Cylinders shall
be complete with pressure-relief valve and associated shut-off valves in good
working order. Empty recovery cylinders are evacuated and, if possible, cooled
before recovery occurs.
The recovery equipment shall be in good working order with a set of instruc-
tions concerning the equipment that is at hand and shall be suitable for the
recovery of all appropriate refrigerants including, when applicable,
fl
ammable
refrigerants. In addition, a set of calibrated weighing scales shall be available
and in good working order. Hoses shall be complete with leak-free disconnect
couplings and in good condition. Before using the recovery machine, check
that it is in satisfactory working order, has been properly maintained and that
any associated electrical components are sealed to prevent ignition in the
event of a refrigerant release. Consult manufacturer if in doubt.
The recovered refrigerant shall be returned to the refrigerant supplier in the
correct recovery cylinder and the relevant waste transfer note arranged. Do
not mix refrigerants in recovery units and especially not in cylinders.
If compressors or compressor oils are to be removed, ensure that they have
been evacuated to an acceptable level to make certain that
fl
ammable re-
frigerant does not remain within the lubricant. The evacuation process shall
Summary of Contents for Arido SDHM-10L
Page 2: ...GB ENGLISH 3 GR EΛΛΗΝΙΚΑ 30 BG БЪЛГАРСКИ 61 ...
Page 93: ...93 NOTES ...