Control
Page 48 Total 145
●For the heat pump, the “
Cool
” mode is allowed; for the heating only unit, “
Cool+ Hot water
” and
“
Cool
” are unallowable.
●This setting can be memorized upon power failure.
3.2.2.2 Fast Hot Water
[Operation Instructions]
★
At the function setting page with the unit turned off, by touching “
Fast hot water
”, the display panel
will go to the
corresponding setting page, where desired option can be selected. Then by pressing “
OK
”
this setting will be saved and the display panel will back to the function setting page.
[Notes]
:
●This function can be set to “
On
” only when the water tank is available. When the water tank is
unavailable, this function will be reserved.
●It will be memorized upon power failure.
3.2.2.3 Cool + hot water
[Operation Instructions]
★
At the function setting page with the unit turned off, by touching “
Cool + hot water
”, the display
panel will go to the corresponding setting page, where desired option can be selected. Then by
pressing “
OK
” this setting will be saved and the display panel will back to the function setting page.
[Notes]
●When the water tank is unavailable, it will be reserved; when it is unavailable, the default priority will
be given to “
How water
”.
●It will be memorized upon power failure.
3.2.2.4 Heat + hot water
[Operation Instructions]
★
At the function setting page with the unit turned off, by touching “
Heat + hot water
”, the display panel
will go to the corresponding setting page, where desired option can be selected. Then by pressing
“
OK
” this setting will be saved and the display panel will back to the function setting page.
[Notes]
●When the water tank is unavailable, it will be reserved; when it is unavailable, the default priority will
be given to “
How water
”.
●It will be memorized upon power failure.
3.2.2.5 Quiet Mode
[Operation Instructions]
★
At the function setting page with the unit turned o
ff, by touching “
Quiet mode
”, there will be a choice
box, where “Quiet mode” can be set to “On”, “Off”, or “Timer”.
★
When it is set to “
Timer
”, it is also required to set the “
Start timer
” and “
End timer
”. Unless otherwise
stated, otherwise time setting is all the same.
Summary of Contents for S-THERM GSH-100ERB
Page 5: ...Engineering Data Page 1 Total 145 ENGINEERING DATA...
Page 15: ...Engineering Data Page 12 Total 145 2 Outline Dimensions GSH 60IRB GSH 80IRB GSH 100IRB...
Page 16: ...Engineering Data Page 13 Total 145 GSH 80ERB GSH 100ERB GSH 60ERB...
Page 18: ...Engineering Data Page 15 Total 145 SMH 80ERB...
Page 21: ...SMH 100ERB Engineering Data...
Page 23: ...SMH 60IRB...
Page 24: ...SMH 60ERB...
Page 26: ...Design and Selection Page 19 Total 145 DESIGN SELECTION...
Page 40: ...Control Page 33 Total 145 UNIT CONTROL...
Page 83: ...Control Page 76 Total 145 2 Open Ewpe Smart APP and click Sign up for registration...
Page 85: ...Control Page 78 Total 145 4 Click at the right upper corner of homepage to add device...
Page 88: ...Control Page 81 Total 145 3 3 2 Setting of Main Functions 1 Set mode and temperature...
Page 91: ...Control Page 84 Total 145...
Page 93: ...Control Page 86 Total 145 3 3 3 3 Feedback Click Feedback to submit feedback...
Page 94: ...Unit Installation Page 87 Total 145 UNIT INSTALLATION...
Page 104: ...Unit Installation Page 97 Total 145 GSH 60ERB GSH 80IRB GSH 100IRB...
Page 112: ...Unit Installation Page 105 Total 145 4 6 4 Outline dimension of indoor unit...
Page 118: ...Unit Installation Page 111 Total 145...
Page 125: ...Unit Installation Page 118 Total 145 GSH 80ERB GSH 100ERB GSH 60ERB...