IQ-SA-360-FM 251012:IQ-SA-360-CS-W.qxd 10/26/12 5:40 PM Page 10
SECTION FIVE
TECHNICAL SPECIFICATIONS
Detection Range
Detection Angle
Power Supply
Maximum Switchable Load
Time On Adjustment
Dusk Level Adjustment
Environmental Protection
Up to 6 metres diameter (3m Radius) at mounting
height of 2.5m
360º
230 V AC ~ 50Hz
2000W (20 x 100W GLS) Incandescent
500W Fluorescent
200W (inductive load, cosѲ = 0.2)
5
seconds - 15 minutes
Day & night or night only operation
IP44
(suitable for sheltered outdoor use)
If you experience problems refer to Troubleshooting Guide.
If problems still exist, do not immediately return the unit to store.
Telephone the Simx Customer Helpline
NZL: 64 9 259 1662
Weekdays 9.00am – 5.00pm
Email: [email protected]
Website: www.simx.co.nz
Qualified Customer Support Co-ordinators will be on-line to assist in resolving your query.
IQ-SA-360-FM 251012:IQ-SA-360-CS-W.qxd 10/26/12 5:40 PM Page 8
SETTING UP FOR AUTOMATIC OPERATION.
When walk tests are complete, the unit can be switched to automatic operation :
To access the controls use a knife or thin flat blade screwdriver to gently level (see diagram E) the
unit clear of the ceiling. Hold in position against the spring pressure while making adjustment.
The TIME setting controls how long the unit remains illuminated following activation & after all
motion ceases. The minimum time (fully anti-clockwise) is approx. 5 seconds, whilst the maximum
time (fully clockwise) is approx. 15 minutes. Set the control to the desired setting between these
limits.
The DUSK control determines the level of darkness required for the unit to start operating. The
setting is best achieved by the procedure below:
Set the DUSK control knob fully anti-clockwise
. The unit will now start operating at dusk.
If you require the light to activate earlier, wait until the ambient light level reaches the level of
darkness at which you wish the lamp to become operative, SLOWLY (a small step at a time) rotate
the control in a clockwise direction until a point is reached where the lamp illuminates in response
to a hand moving below the unit. Leave the control set at this point.
At this position, the unit should become operative at approximately the same level of darkness
each evening. Observe the operation of the unit. If the unit is starting to operate too early (ie. when
it is quite light), adjust the control slightly anti-clockwise. If the unit starts to operate too late (ie.
dusk), adjust the control slightly clockwise.
Continue to adjust until the unit operates as desired.
Once the unit is set up as desired, ease the unit back into position under spring pressure.
MANUAL OVERRIDE MODE
The light can be switched on for longer time periods by use of the
Manual Override Mode
.
This can be activated at night by using the isolation switch.
Switch the isolation switch twice (OFF/ON, OFF/ON) within 2 seconds. The unit will now illuminate
continuously until dawn or until it is switched back into
Detection Mode
.
To return to Detection Mode, switch the isolation switch off and then back on again within 1
second.
IMPORTANT INFORMATION : LIGHT POLLUTION & CONSIDERATE LITHTING
Please be aware of the annoyance over-lighting an area can cause to your immediate
neighbours. Light pollution caused by incorrectly installing a unit or over-lighting an area can be
limited by carefully considering the location and position of your unit before installation. The light
spread on all halogen floodlights can be reduced by angling the floodlight downwards on the
mounting bracket. This will also concentrate the light on your property and limit the potential
inconvenience of the light shinning into your neghbours windows etc.
Please see
Selecting a Location
for information on choosing the optimum location for any
security light controlled by this unit.
The TIME setting controls how long the unit remains illuminated following activation & after
all motion ceases. The minimum time (fully anti-clockwise) is approx. 5 seconds, whilst the
maximum time (fully clockwise) is approx. 15 minutes. Set the control to the desired setting
between these limits.