SECTION FIVE

  

TECHNICAL SPECIFICATIONS

 

 

Detection Range

 

Detection Angle

 

Power Supply

 

Maximum Switchable Load

 

 

 

 

Time On Adjustment

 

Dusk Level Adjustment

 

Environmental Protection

 

Up to 6 metres diameter (3m Radius) at mounting

 

height of 2.5m

 

360º

 

 

230 V AC ~ 50Hz

 

 

2000W (20 x 100W GLS) Incandescent

 

500W Fluorescent

 

200W (inductive load, cosѲ = 0.2)

 

seconds - 15 minutes

 

Day & night or night only operation

 

IP44 

(suitable for sheltered outdoor use)

 

 

  

 

 

 

 

 

 

 

 

 

 

 

 

If you experience problems refer to Troubleshooting Guide.

 

If problems still exist, do not immediately return the unit to store.

 

 

Telephone the Simx Customer Helpline

 

NZL:  64 9 259 1662

 

Weekdays 9.00am – 5.00pm

 

Email: [email protected]

 

Website: www.simx.co.nz

 

 

Qualified Customer Support Co-ordinators will be on-line to assist in resolving your query.

 

IQ-SA-360-FM 251012:IQ-SA-360-CS-W.qxd  10/26/12  5:40 PM  Page 8 

 

 

 

SETTING UP FOR AUTOMATIC OPERATION.

 

When walk tests are complete, the unit can be switched to automatic operation :

 

 

To access the controls use a knife or thin flat blade screwdriver to gently level (see diagram E) the

 

unit clear of the ceiling. Hold in position against the spring pressure while making adjustment.

 

 

The TIME setting controls how long the unit remains illuminated following activation & after all

 

motion ceases. The minimum time (fully anti-clockwise) is approx. 5 seconds, whilst the maximum

 

time (fully clockwise) is approx. 15 minutes. Set the control to the desired setting between these

 

limits.

 

 

The DUSK control determines the level of darkness required for the unit to start operating. The

 

setting is best achieved by the procedure below:

 

 

Set the DUSK control knob fully anti-clockwise

. The unit will now start operating at dusk.

 

 

If you require the light to activate earlier, wait until the ambient light level reaches the level of

 

darkness at which you wish the lamp to become operative, SLOWLY (a small step at a time) rotate

 

the control in a clockwise direction until a point is reached where the lamp illuminates in response

 

to a hand moving below the unit. Leave the control set at this point.

 

 

At this position, the unit should become operative at approximately the same level of darkness

 

each evening. Observe the operation of the unit. If the unit is starting to operate too early (ie. when

 

it is quite light), adjust the control slightly anti-clockwise. If the unit starts to operate too late (ie.

 

dusk), adjust the control slightly clockwise.

 

 

Continue to adjust until the unit operates as desired.

 

 

Once the unit is set up as desired, ease the unit back into position under spring pressure.

 

 

 

MANUAL OVERRIDE MODE

 

 

The light can be switched on for longer time periods by use of the 

Manual Override Mode

.

 

This can be activated at night by using the isolation switch.

 

 

Switch the isolation switch twice (OFF/ON, OFF/ON) within 2 seconds. The unit will now illuminate

 

continuously until dawn or until it is switched back into 

Detection Mode

.

 

 

To return to Detection Mode, switch the isolation switch off and then back on again within 1

 

second.

 

 

IMPORTANT INFORMATION : LIGHT POLLUTION & CONSIDERATE LITHTING

 

 

Please be aware of the annoyance over-lighting an area can cause to your immediate

 

neighbours. Light pollution caused by incorrectly installing a unit or over-lighting an area can be

 

limited by carefully considering the location and position of your unit before installation. The light

 

spread on all halogen floodlights can be reduced by angling the floodlight downwards on the

 

mounting bracket. This will also concentrate the light on your property and limit the potential

 

inconvenience of the light shinning into your neghbours windows etc.

 

 

Please see 

Selecting a Location 

for information on choosing the optimum location for any

 

security light controlled by this unit.

 

The TIME setting controls how long the unit remains illuminated following activation & after 

all motion ceases. The minimum time (fully anti-clockwise) is approx. 5 seconds, whilst the 

maximum time (fully clockwise) is approx. 15 minutes. Set the control to the desired setting 

between these limits.

Summary of Contents for LHT0142

Page 1: ...V1 0 02 12 PIR MOTION DETECTOR INSTALLATION MANUAL LHT0142 ...

Page 2: ... Less Sensitive Lens Mask Restrict short detection Restrict long detection Restrict detection directly under sensor SIDE VIEW TOP VIEW 360º 2 5m 6m More Sensitive ...

Page 3: ...MATION This product is suitable for use only with a supply voltage of 230 240V AC 50Hz All electrical work must be carried out in accordance with local and national electrical codes as applicable We strongly recommend that thissensor is installed by a registered electrician Always switch power off prior to installation A means of mains power isolation must be installed on the circuit for the purpo...

Page 4: ...live supply from AC mains to the output load via the contacts Locators Locating springs pulled back Cable clamps x2 Locating springs fitted position Sensor In the above illustration The L1 L2 terminals are used to control a DC load or if the load uses a different phase or voltage supply from the AC mains in Factory fitted bridge must be removed to isolated L1 L2 terminals from AC mains in Wiring c...

Page 5: ...g human body needs to cross enter one of these zones to activate the sensor The best all round coverage is achieved with the unit mounted at the optimum height of 2 5m Careful positioning of the sensor will be required to ensure optimum performance See diagram A detailing detection range and direction The sensor is more sensitive to movement ACROSS its field of vision than to movement directly TOW...

Page 6: ... as follows NEUTRAL Blue N EARTH Green Yellow LIVE Brown L Connect the fourth core lighting live of the four core cable if used to the L1 terminal block or the second 3 core cable from the lighting to L1 brown N blue and E green yellow SWITCHED LIVE L1 2 Switching DC loads or loads which use a different phase or voltage supply from the AC mains see diagram F Remove the factory fitted bridge wire C...

Page 7: ...oximately 1 2 minutes the lamp will extinguish Try to remain outside the detection area during the warm up period Walk around the sensor to establish the detection area The sensor will detect within an approximately six metres diameter circle from the centre of the sensor location with 2 5m ceiling height As you cross a detection zone the lamp will illuminate Now stand still until the lamp extingu...

Page 8: ...ts to operate too late ie dusk adjust the control slightly clockwise Continue to adjust until the unit operates as desired Once the unit is set up as desired ease the unit back into position under spring pressure MANUAL OVERRIDE MODE The light can be switched on for longer time periods by use of the Manual Override Mode This can be activated at night by using the isolation switch Switch the isolat...

Page 9: ... you experience problems refer to Troubleshooting Guide If problems still exist do not immediately return the unit to store Telephone the Simx Customer Helpline NZL 64 9 259 1662 Weekdays 9 00am 5 00pm Email sales simx co nz Website www simx co nz Qualified Customer Support Co ordinators will be on line to assist in resolving your query 5 seconds 15 minutes Product Complies with EN 60669 2 1 2004 ...

Page 10: ...Check that the power is switched ON at the circuit breaker internal wall switch Turn OFF the power to the unit and check the wiring connections Check the lamp If the lamp has failed replace Ensure that the lamp is seated correctly in the lampholder Please note that the unit will not detect through glass The level of ambient light in the area may be too bright to allow operation at the current DUSK...