Troubleshooting

 - Check fuse

  - Confirm that 120VAC is supplied to terminals 3 and 4

 - Confirm that the receiver code has been memorized (see MEMORIZING

     TRANSMITTER CODES WITH THE RECEIVER on reverse side of this page)
  - Make sure you have generated a code for that button on the transmitter (see SETTING CODES IN
    THE TRANSMITTERS on the reverse side of this page)

 - Make sure the jumper is in terminals 8-9 if no safety device is used.

  - If the jumper is in terminals 8-9 and the receiver still switches in just one direction, the transmitter
    code may have been memorized as either an up or down signal. Delete the transmitter’s code
    from the receiver memory (see ERRASING RECEIVER MEMORY on the reverse side of this page). 
    Then with dip switch 1 and 2 on, have the receiver memorize the transmitter’s code again (see
    MEMORIZING TRANSMITTER CODES WITH THE RECEIVER on the reverse side of this page)
  - Check limit settings on the motor.

 - The timed run on the receiver is set too low. Increase the run time by 

following the instructions in the paragraph “Run time programming (SW1) on page 2.

 - Make sure the transmitter has generated a code for that button (see  SETTING CODES IN

     THE TRANSMITTER on the reverse side of this page)
  - If the led LD is on continuosly, the receiver memory is full (has 24 codes memorized). Delete
    some of the codes (see ERASING RECEIVER MEMORY on the reverse side of this page)

 - Make sure the receiver is as far as possible from other receivers, metal objects, EMI

    sources (floresent lights, transformers, computers, etc...) Try the receiver in different locations if
    possible before hard wiring.
  - If the receiver is mounted in a metal enclosure or in a remote location from where the 
    transmitters will be used with metal or other dense material in the line of sight, the receiver’s 
    antenna can be remotely located nearer to the area the transmitters will be used in (see
    Installation on this page).

Problem: No response from the receiver
Solutions if led PW is off

Soultions if led PW is on

Problem: Receiver only switches in one direction
Solutions

Problem: Motor stops/receiver turns off before the motor reaches the limit.
Solution

Problem: The receiver will not memorize a code from a button on the transmitter
Solutions

Problem: Range is poor
Solutions

TRAN202

TRAN204

TRAN212

TRANWS200

RC200

                        SIMU U.S Inc.,

   6100 Broken Sound Parkway N.W., #14

                 Boca Raton, FL 33487

Phone: 561-995-0335   FAX: 561-995-7502

Description

Use

Transmitters

Receivers

Installation

Electrical connections

Terminals

TECHNICAL SPECIFICATIONS

Receiver

Transmitter

The (X) 200 radio control system consists of one or more transmitters and one or more receivers
which can be combined to meet the specific needs of a wide variety of systems.
The (X) 200 control has a highly reliable and

 system that uses an algorithm to 

recognize only specific variations of the original transmitted code. The receiver is able to memorize

 This allows a receiver to be activated by multiple 

transmitters.

The (x) 200 radio control can be used with Type 3.5, Type 5 and Type 6 120VAC SIMU motors. One
RC200 is required for each motor unless used with SIMU group control relays (RI2, RI3, and GI2).
Each RC200 receiver can be controlled individually from 1 channel (1 button on a transmitter)
when the code is programmed into the RC200 in sequencing mode (open-stop-close-stop..). using
dip switch SW1(on/on). Groups of RC200 receivers can be controlled together by programming 
one button as an open for all receivers in a group using dip switch SW1 (on/off) and one button on
the transmitter as close using dip switch SW1 (off/on).
 

TRAN202           Two channel transmitter                         

2 Buttons

TRAN204           Four channel transmitter                       

4 Buttons

TRAN212           Twelve channel transmitter                    

4 Buttons and A-B-C slide switch

TRANWS200  Four channel wall-switch transmitter       

4 Buttons

RC200             Motor control receiver in surface external box
RC210             Motor control receiver recessable in plastic 3 gang switch box (interior only)
RC201             12/24VDC 2 channel dry contact output receiver

 Disconnect power before installing.

- High voltage 120VAC wires must pass through the holes marked “A” (see fig. 9) 
- Low voltage wires must pass through the holes marked “B” (see fig. 9) and must be routed 
  separately from the high voltage wires.

secure rolling code

24 different codes in its non volatile memory.

IMPORTANT : For installation by a qualified electrician in accordance with local 

   electrical codes.
- CAUTION: RISK OF ELECTRICAL SHOCK.

The receiver bracket should be mounted to the wall with the included screws. The receiver can then
be slid onto the bracket. If mounted in an exposed location, the receiver must be mounted with

holes marked A and B (see fig. 9) facing down. Receivers should not be mounted within 5 feet of 

each other. Do not mount the receiver in a metal box, near metal, or near EMI sources. It is 
recommended that the range of the unit be tested before permanently wiring the receiver. If range is
poor, often relocating the receiver by a few feet can drastically improve the reception. If the 
receiver must be installed in a metal box or located in a remote location, the antenna can be
remotely located. Connect the shield of a coaxial cable to terminal 12 and the center conductor
to terminal 13. Run the cable to a clear location near where the transmitter will be used and strip
the shielding off the last 17cm (exact length of antenna supplied with unit)

!

1-2      Ground (Motor Green)
3          Hot 120 VAC 60HZ
4          Neutral     
5          Motor direction 1 (Motor Black)
6          Motor direction 2 (Motor Red)
7          Motor common (Motor White)
8-9       N.C. low voltage input for safety device. Jumper must be installed if safety device not used
10-11  N.O. low voltage input with sequencing function (open-stop-close-stop-open...) for single 
             throw, single pole low voltage switch (Ref# SPBS.W) 
12        Antenna ground
13        Antenna connection for 17cm wire supplied with receiver. The antenna can be remotely

            located using 50 Ohm coaxial cable as described above in “Installation”      

- Reception frequency........................................................................................................433.92MHz
- Local emission..........................................................................................................................<2nW
- Antenna input impedance..................................................................................................50 Ohms
- Sensitivity.......................................................................................................................................1uV
- Power supply............................................................................................................120VAC 50-60Hz
- Operating temperature range.....................................................................................-20 C...+60 C

- Carrier frequency.............................................................................................................433.92MHz
- Carrier frequency tolerance.................................................................................................+75MHz
- Band width............................................................................................................................>25kHz
- Power supply (alkaline battery GP23A)......................................................................12V+10%
- Maximum power consumption..................................................................................................25mA

- Operating temperature range....................................................................................-10 C...+55 C

NOTE: This equipment LH8TX-S435 and LH8RP-S435 has been tested and found to comply with limits for a 

These limits are designed to provide reasonable protection
against harmful interference to radio communications.
However, there is no guarantee that interference will not occur in a particular installation. If this
equipment does cause harmful interference to radio or television reception, which can be 
determined by turning the equipment off and on, the user is advised to try and correct the 
situation by taking one or more of the following measures:
D       Reorientate the receiving device
A       Increase the distance between the equipment and the receiver
S       Connect the equipment to a socket which is on a different branch circuit than the receiver

S       Consult your dealer or an experienced radio/TV technician for help

ZVL408.01-P1 Mod: 18-04-2008 

class B digital device, according to part 15 of FCC rules. 

Reviews: