4/5
- Press the transmitter
PROG
Key for approximately
one second.
The motor will run for 0,5 second in one direction and then in the other.
Programming the first individual control point
5
This operation can only be performed from the transmitter that was used for operation 4.1.
Your transmitter is now programmed to control the motor in stable mode.
PROG 1s.
1
PROG ≤ 1s.
2
PROG ≤ 1s.
2
PROG ≥ 3s.
1
PROG ≥ 3s.
1
6.2- Confirm the operation from the new transmitter
you want to program:
- Press the
PROG
key of the transmitter for
1 second.
The motor
will run for 0,5 second in one direction and then in the other.
6.1- Open the memory of the receiver from the control
transmitter:
- Press the
PROG
key of the transmitter for about
3 seconds
. The
motor will run for 0,5 second in one direction and then in the other.
Programming a new (individual, group or general) control point
6
- For group controls, repeat operations 6.1 and 6.2 for each motor in the group.
- For general controls, repeat operations 6.1 and 6.2 for each motor in the installation.
- To delete an transmitter from the memory of a motor, perform operations 6.1 with a programmed transmitter, then perform
the operation 6.2 with the transmitter to be deleted.
Programming a sensor
7
7.1- Open the memory of the motor from the individual
control transmitter:
- Press the
PROG
key of the transmitter for about
3 seconds
until the
motor jogs in both directions.
7.2- Confirm the operation from the sensor you wish to
add:
- Press the
PROG
key of the sensor less than
1 second
. The motor
will jog in both directions.
- For group controls, repeat operations 7,1 and 7,2 for each motor in the group.
- To delete a sensor from the motor’s memory: Perform operation 7.1 from the individual control transmitter and operation 7.2
from the automatic control to be deleted.
Recommendations when using a sensor:
If the Wind sensor on an installation is changed or deleted, it is important to
delete it from the memory of all the motors in which it was programmed: perform operations a with a programmed transmitter,
then perform the operation b with the sensor to be deleted.
If you do not want to use this transmitter as the individual control:
- cut the power supply (2 seconds minimum).
- repeat the opération 4.1* with a new transmitter and then go to step §5.