2/5
2
1
10 Nm max.
(DMI6 120 : 20Nm max.)
!
85 Nm max.
!
Wiring
2
Compatible transmitters
3
End limit adjustement
4
- You must have the possibility to switch off
individually each motor.
- Attach cables to prevent any contact with moving
parts.
- If the motor is used outdoors and if the power
supply cable is of the H05-VVF type, then run the
cable in a UV-resistant conduit, e.g. trunking.
PE
L
N
230V~50Hz
(12 transmitters max./3 sensors max. for one motor)
2
1
3
3
4
4
5
5
1 : 1/5 channels Wall Hz transmitter / Memory Hz
2 : 1/5 channels / SUN Mobile Hz transmitter
3 : Color Multi 16 / Timer Easy / Timer Multi transmitters
4 : Windy Hz Accel
5 : EOSUN Hz VS
Location of the PROG key on Hz transmitters:
Do not position the transmitter near metal in order to
avoid range losses.
If the installation includes several motors, only one motor is to be powered during this programming procedure
(4,1). It will eliminate interferences with the other motor during the procedure.
5s.
§4.3
§4.3
4.1-Learning mode:
- Switch the motor ON.
- Simultaneously press the UP and DOWN
keys of a Hz transmitter. The
motor will run for 0,5 second in one direction, then in the other.
The transmitter
now controls the motor in unstable mode, move to stage 4.2
4.2- Checking the rotation direction:
Press the UP key of the transmitter:
a- If the motorized tube runs in the UP direction, move to next stage (4.3).
b- If the motorized tube
runs in the DOWN direction
, reverse the rotation direction by pressing the
Stop key for at least 5
seconds
.
The motor will run for 0,5 second in one direction, then in the other direction. Move to the stage 4.3.
ON
Blue
Brown
Green / yellow