26 27 28 29 30 31 32 33 34 35 36
Remove bridges between connectors 26 and 30,
26 and 31 and instead make bridges between:
5 : phase 1
6 : phase 2
7 : phase 3
26 - 30 : end limit direction 1 (NC)
26 - 31 : end limit direction 2 (NC)
1
2
3
4
5
6
7
M1
M2
M3
8
9
JP1
JP4
The earth must be connected.
U V W
XY Z 1 2
3 4
5 6
SAFETY BRAKE
3/8
3.3 - Motor connection
SINGLE PHASE MOTOR
230V - 50Hz
THREE-PHASES MOTOR
400V - 50Hz
On the T8 motor, the manual override has to be in series on the common (N)
3.4 - Safety accessories power supply connection:
SIMU photo-cells barrier power supply
SIMU access safety edge power supply
If mode “maintained push”, go directly to chapter 3.7
26 27 28 29 30 31 32 33 34 35 36
Make bridges between connectors:
26 and 30
26 and 31
5 : direction 1 - 6 : neutral - 7 : direction 2
1
2
3
4
5
6
7
8
9
JP1
JP4
The earth must be connected.
S1 N
S2
2
1
3
GREEN / YELLOW
230V-50Hz
BLUE
BROWN
BLACK
PE
N
L
SAFETY BRAKE
1
2
3