The echo strength (A) changes with time. The minimum level of detection (B) is adjusted up
or down with the
Gain
function. Increasing the
Gain
with a more positive number reduces
the minimum level, and this increases the sensitivity. Only echoes over the minimum level
are shown in the echogram (C).
Do not confuse this
Gain
setting with the
TVG
(Time Varied Gain) setting.
Tip
During normal operating conditions we recommend that you keep the gain between 15 and
30. If you need to adjust the gain "from scratch" disable AGC (Automatic Gain Control) and
RCG (Reverberation Controlled Gain) to see the immediate effect of the gain adjustments.
While you adjust the gain you may find it useful to have a known target (for example an
island) as reference.
Procedure
1
Click in the view you want to activate.
The active view is identified with a thicker border. Unless you use the
Apply to all
function, all changes you make will only be applied to this view.
2
Turn the relevant rotary switch to make the adjustment.
Tip
The Operating Panel is fitted with three rotary switches. The switches are identified
with numbers. Each switch can be assigned a function related to range, gain or
bearing. Investigate the functionality provided on the
Operating Panel
page. This page
is located in the
Installation
dialog box.
Optionally:
3
Observe the
Main
menu.
Its default location is on the right side of the SX90 presentation.
Simrad SX90 Quick Start Guide