Wind alarm
The wind alarm can be set for high and low wind speeds.
The wind shift alarm will monitor the wind angle. The
reference angle is set when the alarm is turned on,
and reset to present wind angle when an alarm is
acknowledged.
Alarm
Range
Change per
step
Default
value
High speed
Off - 60.0 kn
1–50:
1 kn
50–60:
5 kn
Off
Low speed
Off - 60.0 kn
1–50:
1 kn
50–60:
5 kn
Off
Shift
5° - 90°M
1°M
Off