Ethernet
The Processing unit can output data on Ethernet from terminal
J60. In the
Ethernet
submenu the IP address, netmask, IP port
number and output format have to be specified. For the NMEA
format the messages GGA, GLL, VTG, HDT, ROT and RRE are
included.
IP Address
:
Default setting: 010 000 021 030.
IP Netmast
:
Default setting: 255 255 255 000.
Format
:
Format on Ethernet line. The following
selections are available:
NMEA
and
None
.
WARNING!
If “None” is selected as output format, no data will be
sent to Ethernet line.
Caution!
A change in IP Address and IP Netmask parameter will not
take effect before the HS50 is restarted!
Note!
The cable to be used has to be a crossed Ethernet cable.
General
The
General
submenu includes selection of height aiding,
velocity filtering, Clock data, NMEA id and Datum.