INSTALLATION
20221081 / F
23
RGC12 Gyro Compass
PROCESSING UNIT
HS50
P203
P204
or
P202,
232 OUT
422+ OUT
422- OUT
GND
RGC12
TERMINAL BOARD
GRXH
GRXL
TB7
Simrad RA40/RA50 Radar
PROCESSING UNIT
P208
HS50
AD10_D
AD10_GND
AD10_C
RADAR
GYRCK-
GYRCK+
GYRCK+
GYRCK-
26
27
9
10
Note!
Requires the optional 36-pins connector 72099 for the Radar.
Software set-up in Radar
1
Go to menu:
MENU
→
SETUP
→
CUSTOM
→
PRESET1
2
Change
Input
from
NMEA
to
10 BIT
3
Change
Head
from
TRUE
to
MAGNETIC