36 |
System Configuration |
GN70/MX610/MX612 Operator and Installation Manual
Reset Procedures
In order to access the RESET functionality, the following software versions have to be in place:
•
GN70/MX61x CDU - s/w version 1.0.42.235 (or newer),
•
MX61xJB junction box - s/w version 1100 100121 (or newer)
How to RESET the Junction Box: (MX610JB & MX612JB)
1.
Press the
MENU
key.
2.
Scroll to Tools & Settings, press
ENT
.
3.
Scroll to
NETWORK, press
ENT
.
4.
Scroll to “NMEA Over MX61xJB”, press
ENT.
5.
Scroll to either “Restore to Default” or “Power Reset”, press
ENT.
6.
Press the
CLR
key repeatedly or press any hot keys to exit.
MX612 with 12 Ports
MX610 with 4 Ports
Where:
•
Power Reset - cycles the power to the junction box. High speed ports 3, 7 and 11 will reset to
19,200.
•
Restore to default - restores baud rate of ports as per the table below.
Port#
MX610
MX612
Description
MXJB-NMEA1
4800
4800
NMEA 0183
MXJB-NMEA2
4800
4800
NMEA 0183 Out & RTCM In port
MXJB-NMEA3*
19,200
19,200 NMEA 0183 - Antenna Port
MXJB-NMEA4
4800
4800
NMEA 0183
MXJB-NMEA5
-
4800
NMEA 0183
MXJB-NMEA6
-
4800
NMEA 0183 Out & RTCM In port
MXJB-NMEA7*
-
19,200 NMEA 0183
MXJB-NMEA8
-
4800
NMEA 0183
MXJB-NMEA9
-
4800
NMEA 0183
MXJB-NMEA10
-
4800
NMEA 0183 Out & RTCM In port
MXJB-NMEA11*
-
19,200 NMEA 0183
MXJB-NMEA12
-
4800
NMEA 0183
¼
*Note
:
The ports 3, 7 and 11 are dedicated high speed ports and will reset to 19,200
baud after a power reset.