![Simrad ES 18 - DATASHEET REV C Installation Manual Download Page 16](http://html1.mh-extra.com/html/simrad/es-18-datasheet-rev-c/es-18-datasheet-rev-c_installation-manual_1279159016.webp)
14
404770/B
Rules for transducer handling
To secure long life and accurate results, the transducer must be handled correctly.
A transducer must always be handled as a delicate instrument. Incorrect actions may
damage the transducer beyond repair. Observe these transducer handling rules:
1
Do not
activate the transducer when it is out of the water.
2
Do not
handle the transducer roughly. Avoid impacts.
3
Do not
expose the transducer to direct sunlight or excessive heat.
4
Do not
use high-pressure water, sandblasting, metal tools or strong solvents to
clean the transducer face.
5
Do not
damage the outer protective skin of the transducer face.
6
Do not
lift the transducer by the cable.
7
Do not
step on the transducer cable.
8
Do not
damage the transducer cable, and avoid exposure to sharp objects.
Transport protection
Some transducers are delivered with a cover plate to protect the face during transport
and installation. Let this plate stay on as long as possible, but do not forget to remove
it before the vessel goes to sea.
Cleaning and painting the transducer face
During normal use, the transducer is subjected to biological fouling. If this marine
growth is excessive, it will reduce the performance of the ES18.
The transducer has not been designed with any protection against biological fouling.
Whenever opportunity arise, typically when the vessel is dry-docked, the transducer face
must be cleaned for shells and other marine growth.
• Be careful so that you do not accidentally make cuts or inflict other physical damage
to the transducer face.
• Remove biological fouling carefully using a plastic brush, a suitable synthetic
detergent and fresh water. Biological material which is strongly rooted in the substrate
can be removed carefully with a piece of wood or plastic.
•
Do not
use high-pressure water, sandblasting, metal tools or strong solvents to clean
the transducer.
Anti-fouling paint may be applied to the transducer face. To minimize the negative
acoustical effects the layer of anti-fouling paint must be as thin as possible.
Simrad ES18 Installation Manual
Summary of Contents for ES 18 - DATASHEET REV C
Page 2: ......
Page 75: ...404770 B 73 Related topics Drawing file page 70 Drawing file...
Page 77: ...404770 B 75 Drawing file...
Page 78: ...76 404770 B Related topics Drawing file page 70 Simrad ES18 Installation Manual...
Page 80: ...78 404770 B Related topics Drawing file page 70 Simrad ES18 Installation Manual...
Page 82: ...80 404770 B Related topics Drawing file page 70 Simrad ES18 Installation Manual...
Page 87: ......
Page 88: ...2020 Kongsberg Maritime...