950-7001001/Iss 1.2
EQ-55 Operators Manual
Page 7.8
Servicing the EQ-55
Kongsberg Simrad Mesotech Ltd.
Port Coquitlam, BC - Canada
7.6.3
Replacing the Power Supply PCB Assembly
Replacing the power supply PCB is the reverse of the removal process. It helps to
arrange the connectors before placing the PCB, so that the connectors may be
accessed easily after the PCB is in place. Use care to ensure that the connectors
are mated correctly with their respective receptacles.
7.6.4
Removing the Display Monitor Assembly.
Remove the entire EQ-55 form it's mounting location. Place the EQ 55 on a clean
surface which will not mar the finish. A static dissipative surface, properly
grounded, and static-dissipative practices for personnel are recommended to
minimize damage to the unit from static electricity.
7.6.5
Remove the drawer assembly ( see section 7.4.1 ).
7.6.6
Remove the Rear Housing
Remove the 8 Philips screws that are on the edges behind the front bezel. Lift off
the main housing and unplug the fan connector.
7.6.7
Removing the Bezel from the Chassis
Note that it is not necessary to remove the bezel to gain assess to or for removal of
the circuit board. In removing the bezel from the monitor chassis, it must be
remembered that the CRT is mounted to the bezel, and the bezel must therefore
be properly supported when the two are separated.
7.6.8
Replacing the Display Monitor Assembly.
Replacing the display monitor is the reverse of the removal process. ( see section
7.6 )