background image

BSM-2 Installation manual | 7

E

NG

L

IS

H

Installation and wiring

Mounting location

Before installing the BSM-2, consider location and cable 

runs necessary to connect the module to display unit, 

transducer and power source.

The mounting location must allow for required working 

area when connecting the cables. Also ensure that the 

location allows viewing the unit’s LED indicators.

The units should be mounted with special regard to the 

units’ environmental protection, temperature range and 

cable length.

The mounting surface needs to be structurally strong, 

with as little vibration as possible. If possible mount the 

unit close to the edges of a panel to minimize vibration.

Do not run the transducer cabling near the BSM-2 power 

cables, any VHF antenna coax cables or any DC or AC 

power cables. Avoid placing Ethernet cables close to VHF 

antennas.

The BSM-2 conforms to the appropriate Electromagnetic 

Compatibility (EMC) standards, but proper installation 

is required to get best use and performance from 

this product. Ensure you have as much separation as 

possible between different electrical equipment, (see 

diagram below). 

X

X

Electromagnetic interference

Gasoline fumes

Vibration

Heat

Sunlight

Salt spray

Physical damage

2.0 m (6.5 ft) Min

1.8 m (6 ft) Min

1.5  m (5 ft) Min

RADAR

Radio or AIS Transmitter

Compass

Summary of Contents for BSM-2

Page 1: ...A brand by Navico Leader in Marine Electronics Manual Simrad BSM 2 Broadband Sounder Module EN DE ES FR IT...

Page 2: ...WAY THAT MAY CAUSE ACCIDENTS DAMAGE OR THAT MAY VIOLATE THE LAW Governing Language This statement any instruction manuals user guides and other information relating to the product Documentation may be...

Page 3: ...n a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to ra...

Page 4: ...wing two conditions 1 this device may not cause interference and 2 this device must accept any interference including interference that may cause undesired operation of the device Warranty The warrant...

Page 5: ...and wiring 7 Mounting location 7 Securing BSM 2 module 8 Wiring 8 General 8 Grounding the unit 9 Wiring diagram 9 Terminal connections 10 Power connection 11 Transducers connection 11 Connecting the B...

Page 6: ...he unit to transducers and display units Separate installation instruction for transducers are included with the transducer package The BSM 2 is compatible with the following displays and systems NSE...

Page 7: ...adapter cable 4 5 m 15 ft 1 Power cable bare wires 2 m 6 5 ft Power and GND 16 gauges Switch connection 18 gauges 1 Terminal block connection kit including 6 Terminal blocks 2 Jumper wires for impeda...

Page 8: ...with as little vibration as possible If possible mount the unit close to the edges of a panel to minimize vibration Do not run the transducer cabling near the BSM 2 power cables any VHF antenna coax...

Page 9: ...he transducer cables connect with screw terminals inside the BSM 2 unit Refer wiring diagram and connection details on the following pages The BSM 2 contains high voltages and specialized parts the op...

Page 10: ...install grounding cable in ground screw hole as indicated on illustration Recommended 16 awg wire Wiring diagram BSM 2 NEP 2 12 24 V DC _ 1 3 2 ref Description 1 Ethernet cable 2 BSM 2 Power cable 3...

Page 11: ...10 0 mm 14 0 mm 3 94 5 51 M16 Power Speed Temperature 1 Temperature 2 6 0 mm 10 0 mm 2 36 3 94 2 Remove the outer sealing nuts from selected cable glands and thread those on to the cables 3 Terminate...

Page 12: ...ot in operation It is recommended that the yellow power cable wire be fitted with an optional on off switch allowing the BSM 2 to be powered off when not in use POWER POS J3 1 NEG ACC PWR 1 3 4 2 Tran...

Page 13: ...am before connecting transducer rEF CoLor FuNCTIoN 1 Orange XID 2 Shield XID ground if available 3 Brown Thermistor XID ground 4 White Thermistor 5 Shield High freq depth shield 6 Black High freq nega...

Page 14: ...w XDCR LOW SPD PWR SPD IN GND SPEED J4 1 XDCR HIGH XDCR Z1 XDCR Z2 XDCR Z3 XDCR XDCR SHIELD IMP SEL J8 1 XDCR Z1 XDCR Z2 XDCR Z3 XDCR XDCR SHIELD IMP SEL J7 1 TEMP LOW TEMP LOW GND XDCR ID LOW J6 1 TE...

Page 15: ...e list connect the jumper to the impedance selector according to the transducer impedance based on the following table HIGH FrEQ LoW FrEQ A 100 Ohm D 100 Ohm B 270 Ohm E 270 Ohm C 400 Ohm F 400 Ohm If...

Page 16: ...settings The transducer s XID wire orange should be connected to the XDCR_ID_ HIGH LOW terminal in the TEMP HIGH LOW connector as shown below TEMP HIGH TEMP HIGH GND XDCR ID HIGH J5 1 1 2 If your tra...

Page 17: ...perational Flashing Red Green Software error or unit reprogrammed Restart the unit If still not ok contact Customer Support Network Off No Ethernet connection Check cable Verify that remote unit is tu...

Page 18: ...ed transducer Power Connector 5 pin Yellow RJ45 Weight 4 8 kg 10 6 lbs Die Cast Aluminum Dimensions WxHxD mm in 340x100x289 mm 13 38x3 94x11 37 inches With watertight glands and connector outside dime...

Page 19: ...Range Dependent to 70ms max CHIRP produces 5X better resolution Impedance 3 taps Accommodates all narrowband used on BSM 1 most Airmar latest Broadband Transducers and SIMRAD COMBI C Max transmit rate...

Page 20: ...nating dual frequency display with CHIRP simultaneous with narrowband With Upper and Lower Limit Zoom size Auto manual x2 x3 x4 x5 x6 x7 x8 user selectable DC voltage requirements Voltage 10 7 32 VDC...

Page 21: ...20 BSM 2 Installation manual Dimensional drawing 340 mm 13 38 320 mm 12 60 100 mm 3 94 109 mm 4 29 250 mm 9 84 289 mm 11 38...

Page 22: ...16 and 7 x 7 beamwidths Depth Temp same as Kongsberg KSV 203005 50 200 Combi D 000 10387 001 700 3001 Combi C 1kW Thru Hull 38 200Khz with 13 x 21 and 7 x 7 beamwidths w HS Fairing Block Depth Temp sa...

Page 23: ...w 22 20 6 6 Array Beamwidths and 12 tilt 12 m 39 4 ft cable 50 240ohms E 200 180ohms B B258 Bronze Thru Hull 50 200Khz Depth Temp w 15 21 3 5 Array Beamwidths and High Speed Fairing Block 12 m 39 4 ft...

Page 24: ...E B265 1kW Bronze Thru Hull 40 60Khz with 21 31 beamwidths 130 210Khz with 6 10 beamwidths w HS Fairing block Depth Temp 12 m 39 4 ft cable 50 40 60 100 400 ohms F 200 130 210 90 250 ohms B R209 3kW T...

Page 25: ...5 135 270 ohms E 200 130 210 90 250 ohms B R399 3kW Tank Kit 25 45Khz with 6 11 x 11 17 beamwidths 130 210Khz with 5 7 beamwidths Depth only 15 m 49 2 ft cable 28 25 45 135 270 ohms E 200 130 210 90 2...

Reviews: