12 | BSM-2 Installation manual
Airmar transducers
The wiring diagram below shows how to connect an
Airmar transducer (R309).
On some models Low frequency XDCR+ wire (yellow) can
be color blue/white.
On some transducer models temperature brown cable is
connected internally to XID GND, and there is no need to
connect bare and brown cable together.
Consult XDCR documentation for correct wiring diagram
before connecting transducer!
rEF.
CoLor
FuNCTIoN
1
Orange
XID
2
Shield
XID ground (if available)
3
Brown
Thermistor (XID ground)
4
White
Thermistor
5
Shield
High freq. depth shield
6
Black
High freq. negative
7
Blue
High freq. positive
8
Shield
Low freq. depth shield
9
Black
Low freq. negative
10
Yellow or blue/white
Low freq. positive
XDCR LOW
SPD PWR
SPD IN
GND
SPEED
J4
1
XDCR HIGH
XDCR Z1
XDCR Z2
XDCR Z3
XDCR -
XDCR +
SHIELD
IMP
SEL
J8
1
XDCR Z1
XDCR Z2
XDCR Z3
XDCR -
XDCR +
SHIELD
IMP
SEL
J7
1
TEMP LOW
TEMP
LOW
GND
XDCR ID LOW
J6
1
TEMP HIGH
TEMP
HIGH
GND
XDCR ID HIGH
J5
1
9
10
5
6
8
7
1 2
3 4