Simrad GC80/GC85 Compact Gyro Compass
106
20221511 / D
Alarm
code
Alarm content
Detailed
code
Possible cause
E-F
MAG/EHS data
abnormal
33
EHS data abnormal. (timeout is 17 sec.)
E-L
EXT. sensor
communication off
30
When EXT. sensor system is stopped or serial signal
from EXT. sensor is cut. (timeout is 15 sec.)
E-n
EXT. sensor data
abnormal
31
EXT. sensor data abnormal.(timeout is 17 sec.)
E-P
LOG(serial)
communication off
28
When LOG (serial) source is stopped or serial signal
from LOG (serial) is cut. (timeout is 15 sec.)
E-U
LOG(serial) data
abnormal
29
LOG (serial) data abnormal.(timeout is 17 sec.)
E-r
E5V is lost
34
E5V (power supply of serial signal) is lost.
E-G
Master bearing is
abnormal
35
When compensation of the bearing by the encorder
signal is not completed.
E-u *1
LOG(contact)
data abnormal
37
LOG (contact) is abnormal.
*1: This alarm code is not displayed to customer.
Summary of Contents for 000-15567-001
Page 1: ...INSTRUCTION MANUAL SIMRAD GC80 85 COMPACT Gyro Compass 20221511D English ...
Page 16: ...Simrad GC80 GC85 Compact Gyro Compass 8 20221511 D THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 30: ...Simrad GC80 GC85 Compact Gyro Compass 22 20221511 D THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 64: ...Simrad GC80 GC85 Compact Gyro Compass 56 20221511 D THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 72: ...Simrad GC80 GC85 Compact Gyro Compass 64 20221511 D THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 84: ...Simrad GC80 GC85 Compact Gyro Compass 76 20221511 D ...
Page 90: ...Simrad GC80 GC85 Compact Gyro Compass 82 20221511 D THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 96: ...Simrad GC80 GC85 Compact Gyro Compass 88 20221511 D THIS PAGE INTENTIONALLY LEFT BLANK ...