ALARM MESSAGES AND CORRECTIVE ACTIONS
20221511 / D
101
Internal power failure in Control unit
Generated when the Control unit’s power supply are over current
or over voltage.
1
Turn OFF the power by pressing the
POWER
button, and
repress the
POWER
button after 20 seconds.
2
If no alarm is activated, continue the start-up procedure as
described in
, page 10.
3
If the alarm is repeated, contact Simrad’s local dealer for
assistance.
Inverter failure
Alarm generated in the Inverter in the Master compass is over
current or over voltage.
1
Turn OFF the power by pressing the
POWER
button, and
repress the
POWER
button after 20 seconds.
2
If no alarm is activated, continue the start-up procedure as
described in
, page 10.
3
If the alarm is repeated, turn OFF the power and check the
inverter fuse, F1:12A.
For location and replacement of the fuses, refer to page 30
onwards.
Zero cross failure
This alarm is generated when the reference angle for the
compass bearing not can be properly detected, or if a fault is
generated in the bearing calculation.
1
Press the
DISP
button until the flashing bearing is
displayed in the LCD.
2
Adjust the bearing with the arrow buttons until the bearing
corresponds to the vessel’s actual bearing, and confirm the
entry with the
ACK/ENT
button.
If the bearing input was accepted by the system, the LCD
will display current bearing without flashing.
3
Report the error to Simrad even if the bearing is accepted
and the alarm removed.
Summary of Contents for 000-15567-001
Page 1: ...INSTRUCTION MANUAL SIMRAD GC80 85 COMPACT Gyro Compass 20221511D English ...
Page 16: ...Simrad GC80 GC85 Compact Gyro Compass 8 20221511 D THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 30: ...Simrad GC80 GC85 Compact Gyro Compass 22 20221511 D THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 64: ...Simrad GC80 GC85 Compact Gyro Compass 56 20221511 D THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 72: ...Simrad GC80 GC85 Compact Gyro Compass 64 20221511 D THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 84: ...Simrad GC80 GC85 Compact Gyro Compass 76 20221511 D ...
Page 90: ...Simrad GC80 GC85 Compact Gyro Compass 82 20221511 D THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 96: ...Simrad GC80 GC85 Compact Gyro Compass 88 20221511 D THIS PAGE INTENTIONALLY LEFT BLANK ...