Repeater failure
No output on single repeaters
1
Check that the repeater is connected to the gyro according
to the repeater’s documentation.
2
Each repeater output has a separate fuse in the Control
unit. Disconnect the power to the Control unit, and check
the fuse for the repeater not working:
-
Step repeater:
F5: 1A
-
Serial repeater:
F1 to F4: 1A
For location and replacement of the fuses, refer to page 32
onwards.
No output on any repeater
1
Disconnect the power to the Control unit, and check the
following fuses:
F8: 6,3A
For location and replacement of the fuses, refer to page 32
onwards.
Failure when powering ON the gyro
compass
If alarm code and are generated simultaneously when the
GC80 system is turned ON, the following procedure should be
used to correct the alarm situation:
1
Press the
POWER
button to turn OFF the system, and
repress the button after 1 second.
2
If the alarm status remains, remove the power to the
system and verify the fuse for the inverter.
For location and replacement of the fuses, refer to page 30
onwards.
Summary of Contents for 000-15567-001
Page 1: ...INSTRUCTION MANUAL SIMRAD GC80 85 COMPACT Gyro Compass 20221511D English ...
Page 16: ...Simrad GC80 GC85 Compact Gyro Compass 8 20221511 D THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 30: ...Simrad GC80 GC85 Compact Gyro Compass 22 20221511 D THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 64: ...Simrad GC80 GC85 Compact Gyro Compass 56 20221511 D THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 72: ...Simrad GC80 GC85 Compact Gyro Compass 64 20221511 D THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 84: ...Simrad GC80 GC85 Compact Gyro Compass 76 20221511 D ...
Page 90: ...Simrad GC80 GC85 Compact Gyro Compass 82 20221511 D THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 96: ...Simrad GC80 GC85 Compact Gyro Compass 88 20221511 D THIS PAGE INTENTIONALLY LEFT BLANK ...