38
!
* = factory default settings
Menu
Category
Parameter
Name
Choices /
Format
Description
Tech
Note
rESEt
SEtuP
ArESEt
diSAbL
*
At SP1
At SP2
At SP3
At SP4
AFtoP1
AFtoP2
Auto Reset Mode
Selects when an auto
reset function is to occur.
Disabled at a set point or
after output times out.
See also the
RSTPOS
parameter in the S
etpnt
Setup
category
4.7
rStbtn
enable
*
diSAbL
Reset Button
Enable or disable front
panel reset button.
4.8
PonrSt
no
*
YES
Power On Reset
Select
whether count reset
event will occur at
power-up.
4.8
End
Exit Programming
Menu
Menu
Category
Parameter
Name
Choices /
Format
Description
Tech
Note
SP4
000040
*
SP4
Set point #2 High.
Values
: -99999 to
999999. Decimal point
will appear according to
the current
Output 2
Source
setting.
4.6
rStPos
000000
*
Reset Position
Count value is set to this
when an Auto or Manual
Reset event occurs.
Values
: -99999 to
999999. Decimal point
will appear according to
the user-programmed
Count DP
position
4.6
www.