19
Table 5. Password Values
2)
If a password is already in the counter, the display will flash between pass, for “Enter
Password,” and the default value, 000.
a)
When the display shows 000, press . Use the arrow keys to change the flashing
digit to the desired number. Press to advance to the next digit.
b)
Press to enter the password as shown. If an incorrect password is entered, ac-
cess denied will flash on the display. Press an arrow key to return to the pass dis-
play.
c)
After entering the correct password, the counter will return to chpass. Press to
change password, or press the key to continue to the Input Setup menu category.
4.2 A/B Channel Options (Input Setup)
The next category in the Programming Mode is the “Input Setup.” Here you can adjust the A
and B channels to the appropriate count modes.
The A channel input may be selected as an Up, Down, Quadrature or Reverse Quadrature* in-
put. As an Up channel, pulses applied to the A input are added to the display. In Down mode,
subtraction occurs. Note that when using Quadrature inputs, appropriate hardware (jumper)
settings may be needed.
* The Reverse Quadrature input allows the user to reverse the count direction of the encoder in
software instead of having to rewire/remount the encoder.
Password Value
Level of Security
000
No Security - Default setting
Allows full access to the Programming Menu and
Quick Access to set points is enabled.
001 - 099
Fully secure
The Programming Menu is secured by password
and Quick Access to set points is disabled.
100 - 999
Quick Access Only
Programming Menu is secured by password,
Quick Access to set points via up and down keys
enabled.
A CHAN
Direction
B CHAN
UP
Up
User defined
DOWN
Down
User defined
QUAD
Up
Not Available
R QUAD
Down
Not Available
Table 6. Channel A Selection
E
N
TE
R
E
N
TE
R
E
N
TE
R
R
E
S
ET
www.
.com
1.800.561.8187