3.
The operating environment is subject to corporate policies, union contracts, OSH
regulations or other external factors which specify that all machinery must have a
safety performance level of PLd or PLe.
In any of these cases, information about the hazard and risk assessment, required safety
function and performance level should be provided to Simpro before placing an order.
Simpro can then specify and quote additional or uprated safety functions, such as:
-
CAT3 Kit
to achieve PLd safety performance
-
CAT4 Kit
to achieve PLe safety performance
-
Additional guarding
-
Remote controls
-
Training of operators
-
Custom signage or floor markings
The CAT3 Kit is the most common Dumpmaster safety function upgrade. It is typically
specified when any of the following conditions apply:
- Intensive 24/7 operating cycle
- Transient or low-skilled operators
- Personnel frequently entering the machine (ie for daily cleaning)
- Corporate or union policies require machinery to have CAT3/PLd safety functions