background image

85 mm

75 mm

34.5 mm

71  mm

29mm

Product Model:

1

7

5

3

2

8

6

4

1. Check parameter setting:

Under normal working conditions, press and release 
the“     ” key once, the screen will display the 
temperature setting value; press and release the “     ” 
key once, the screen will display the difference setting 
value. The display will return to the temperature 
display after 2s.

2. Set parameters:

Under normal working conditions, press “   ” for 3s to 
enter parameter setting function, at this time the 
“Set” indicator will light and the screen displays the 
first menu function “F1”. Press the “     ” or “     ” key to 
move between setting functions. Press the “   ” key and 
the screen then displays the parameter value for the 
current function. The parameter value can be adjusted 
by pressing the “     ” or “     ” key. Pressing and holding 
the “     ” or “     ” key will adjust the parameter’s 
value rapidly. After the desired value is set, press and 
hold the “   ” key for 3s to save the modified parameter 
value and return to the temperature display. If there is 
no key operation for 10s, the system won’t save the 
modified parameter value and the screen returns to 
the temperature display.

The screen displays “Er” if an error occurs during 
parameter setting.

Three digit LED + minus digit + status indicator 
(cool, heat) + set indicator

Key description:

 “   ” key: set key; “     ”key: up key; “     ” 

key: down key; “    ” key: power on/off key

Sensor Wire Length: 2m(including the probe).

Under normal working conditions, pressing and 
holding the “    ” key for 3s will turn off the controller. 
When the controller is switched off, pressing and 
holding the “    ” key for 3s will turn the controller on.

Under normal working conditions, the screen displays 
the current measured temperature value. The 
controller will automatically switch between heating 
and cooling to maintain the set temperature within the 
difference limits.

The controller will turn on the cooling relay (cool 
indicator lit) when the measured temperature value 

 

temperature set value + difference value. If the “cool” 
indicator flashes, it means the cooling function is in 
the compressor delay protection mode. After the 
compressor delay time has elapsed, the cooling relay 
will be switched on. When the measured temperature 
value 

 the temperature set value, the cooling relay is 

switched off and the “cool” indicator is off. The 
controller will turn on the heating relay (heat indicator 
lit) when the measured temperature value 

 

temperature set value – difference value. When the 
measured temperature 

 temperature set value, the 

“heat” indicator lamp is off and the heat relay is 
switched off.

MICROPROCESSOR

CONTROLLED 

HEATING & COOLING

TEMPERATURE CONTROLLER

Tel: 

+44 (0)1684 252080  |  

Fax: 

+44 (0)1684 252680

Email: 

[email protected]

www.simplyaquaria.co.uk

Technical Parameters:

Key Functions:

Product Information:

Typical Wiring Diagram:

This controller is mainly used for precise temperature 
regulation in aquariums and will control both heating 
and cooling devices such as heaters and 
chillers/cooling fans.

This device is a control module only and will 
require wiring.

RC-316M

KEY FEATURES:

• Temperature measuring range -50°C ~ 99°C
• Temperature differential range 0.1°C ~ 10.0°C
• Compressor delay range 1 ~ 10 mins.
• Temperature calibration range -10°C ~ 10°C
• Alarm Function: Audible and visual
• Alarm function range: 0.2°C ~ 5°C of set 

  point temperature
• Display Resolution: 0.1°C
• Accuracy: ± 1°C
• Power supply: 220VAC±15%, 50/60HZ
• Temp Sensor: 1 x 2 metre NTC sensor
• 16A Heating Control (resistive load, such as heater)

  max 1840W
• 16A Cooling Control (inductive load, such as a chiller)

  max 500W
• Operating Temperature Range: 0°C ~ 60°C
• Operating Humidity range: 20% ~ 85%
• Power consumption: 

3W

• Power off memory function: Settings retained

  when power lost

THANK YOU

FOR CHOOSING OUR PRODUCT!

PLEASE READ THIS INSTRUCTION GUIDE

CAREFULLY BEFORE USE.

Product Size:

Display Description:

Operating Instructions:

Indicator status Description:

Indicator

Note

Cool 

indicator

Heat 

indicator

Set 

indicator

Function

On: Cooling switched on; 

Off: cooling switched off; 

Flashing: compressor delay

On: heating switched on; 

Off: heating

On: parameter setting

The Cool & Heat 

indicators can 

NOT be “on” 

simultaneously

Reviews: