Wiring Diagram:

9

15

13

11

10

16

14

12

Example: Set the desired temperature to 25°C +/-
0.3°C, with an alarm set for 25°C +/- 0.7°C.

• Target temperature is set to 25°C as above (F1)
• Cooling differential is set to 0.3°C as above (F2)
• Heating differential is set to 0.3°C as above (F2)
• Alarm differential is set to 0.7°C as above (F5)

As the temperature in the aquarium rises, when it gets
above 25.3°C, the cooling relay will be energized and 
the attached fan/chiller will switch on (after 
compressor delay). The cooling relay will remain 
energised until the aquarium temperature 
reaches 25°C.

As the temperature in the aquarium falls, when it gets
below 24.7°C, the heating relay will be energized and 
the attached heater will switch on. The heating relay 
will remain energised until the aquarium temperature 
reaches 25°C.

If the aquarium temperature falls below 24.3°C or rises 
above 25.7°C, the alarm function will flash the
temperature value and alarm icon (HHH or LLL) 
and also sound an audible alarm.

Pressing any button will mute the audible alarm, but 
the visual alarm/temperature will keep flashing until 
the temperature comes back between 24.3°C ~ 25.7°C.

Assembly:

 Warning: 

The controller should be connected

 

only by Competent persons according to this 

 

user manual and avoid installing in the 

 

below environments:

• Relative humidity >90%, or condensation present
• Temperature <-10°C or >60°C
• Environments that contain flammables/explosives
• Strong vibration or shock
• Exposed to continuous water mist
• Exposed to the dust
• Exposure to corrosive and polluting gas
• Wireless electromagnetic interference or strong

  magnetic fields (near to transmitting antenna or

  switch board room)

Connect the controller according to the above 
diagram, the voltage must within 220VAC±10%.

• 16A Heating Control (resistive load, such as heater) 
  max 1840W
• 16A Cooling Control (inductive load, such as a chiller)
  max 500W

Please install the controller according to the 
following steps:

• Cut out a hole at the installing position: 71×29mm
• Detach the slide fasteners, and place the controller 
  into the hole. (1st step, Figure.a);
• Install the fasteners. 

(

2nd step

Figure.b)

;

Figure.a

Figure.c

Figure.b

After connecting the wires, install the terminal guard 
(3rd step, Figure.c)

How to disassemble the controller from the hole?

Firstly disassemble the 
terminal guard, then 
press the clip

 (

Figure.d

 

sliding backwards to 
disassemble the 
controller.

Figure.d

Notice:

1.

  The power supply should conform to the 

  voltage indicated in the instruction.

2.

 To avoid interference, the sensor lead and

  power leads should be kept apart as much
  as possible.

3.

 Warranty does not cover damages caused by 

  over voltage or over load or incorrect wiring.

4.

 Warranty period is 12 months from purchase.

Sensor wire × 1pc
Slide fastener × 2pcs
User manual × 1

Sensor error:

 The controller activates the sensor error 

alarm mode when the sensor is open circuit or short 
Circuit. The heating and cooling relays are switched 
off and an audible alarm sounds and “EE” is displayed. 
Pressing any key will cancel the alarm sound. The 
controller will return to normal operation when the 
error is cleared.

Temperature error:

 When the measured temperature 

exceeds the temperature measuring range, the 
controller activates the temperature error alarm 
mode. The heating and cooling relays are switched off 
and an audible alarm sounds and “HH” is displayed. 
Pressing any key will cancel the alarm sound. The 
controller will return to normal operation when the 
temperature returns to the normal measuring range.

F1

F2
F3

F4

F5

Temperature set value

Difference set value
Compressor delay time
Temperature

calibration value
Alarm differential

-50°C ~ 99.9°C

0.1°C ~ 10°C

0.2°C ~ 5.0°C

5°C

1~10 minutes

-10°C ~ 10°C

10°C

0.5°C
3 minutes

0°C

Product Size:

Parameter Menu:

Error Description:

Accessory:

Code

Function

Set range

Default