4100U Series MINIPLEX transponders allow 
remotely located initiating and notification 
functions: 

x

Transponder operation is available as standard or with 
local mode operation 

x

Communications with the host fire alarm control panel 
use the Remote Unit Interface (RUI) format 

Initiating functions include: 

x

Conventional initiating device circuit (IDC) support 

x

Addressable device support including TrueAlarm

®

analog sensor compatibility** 

Notification functions include: 

x

Conventional DC notification appliance circuits 

x

Emergency voice/alarm communications 

x

TrueAlert

®

 addressable strobe and horn notification 

Local mode operation provides: 

x

Default local initiating and notification operation in the 
event of a communications loss with the host control panel 

x

Enabling of an optional Local Mode Controller with a 
local alarm sounder, LED status indicators, and 
keyswitch enabled control switches 

x

Support for IDNet™ addressable devices, conventional 
and TrueAlert addressable notification appliances, and 
default output tones from local amplifiers** 

Optional modules include: 

x

Digital or Analog audio riser modules for connection to 
system audio signals 

x

Digital or analog input audio amplifiers with integral 
on-board NACs 

x

Power supplies with or without battery chargers 

x

City Connect modules and RS-232 ports for printers or 
maintenance terminals 

x

Alarm relays, auxiliary relays, additional IDC modules, 
and NAC expansion modules 

Cabinets are equipped with solid doors (beige or 
red) and in two or three bay sizes 

Listed to: 

x

UL Std. 864, Fire Detection and Control (UOJZ), and 
Smoke Control Service (UUKL) 

x

UL Std. 2017, Process Management Equipment (QVAX) 

x

UL Std. 1076, Proprietary Alarm Units-Burglar (APOU) 

x

UL Std. 1730, Smoke Detector Monitor (UULH) 

x

ULC Std. S527-99 

*    See pages 4 and 5 for product that is listed as UL or ULC. This product has been approved by 

the California State Fire Marshal (CSFM) pursuant to Section 13144.1 of the California Health 
and Safety Code. See CSFM Listing 7165-0026:251 (non-high rise) and 7170-0026:250 (high 
rise) for allowable values and/or conditions concerning material presented in this document. It 
is subject to re-examination, revision, and possible cancellation. Accepted for use – City of 
New York Department of Buildings – MEA35-93E. Additional listings may be applicable; 
contact your local Simplex product supplier for the latest status. Listings and approvals under 
Simplex Time Recorder Co. are the property of Tyco Safety Products Westminster. 

On

Off

Auto

On

Off

Auto

On

Off

Auto

On

Off

Auto

On

Off

Auto

On

Off

Auto

On

Off

Auto

On

Off

Auto

Press 

ACK 

l ocated under flashing indicator.

Repe at  operation until  all events are  acknowledged.
Local  tone w ill  sil ence.

AB  C

AC Po wer

D E  F

G H  I

J K   L

M   N   O

P  Q  R

'SP'  ( )

, 0  :

S T  U

V W   X

Y  Z   /

ALARMS

Fire Alarm

Priority 2 Alarm

SYSTEM WARNING S

Superv isory

Trou ble

A larm Silenced

Emergency Operating Instructions

Alarm or Warning  Condit ion

How t o Acknowledge / View Events

How  to Silence Building Signals

System indicator flashing. Tone On.

Press 

Ala rm Silence.

How  to Reset System

Press 

System Reset.

Press 

Ack 

to si lence  tone  device.

Z ON E

1

SI G

2

AUX

3

FB

4

IO

5

I DN et

6

P

7

A

8

L

9

NE T

ADDR

0

DEL

Enter

C/ Exi t

Fire Alarm

Ack

Prior ity 2

Ack

Supv
Ack

Trouble

Ack

Alar m
Silence

Sy stem
Reset

Event
Time

Enable

On
Ar m

Disab le

Off

Disarm

Auto

L amp
Test

Mo re
Info

Menu

Previous

Next

SYSTEM IS NORMAL

08:23:43 am

MON 11-DEC-00

Fire Control

4100U Fire Alarm Control Panel

with Voice Control

ALARM

FIRE

PULL    DOWN

C
A
U
T
I
O
N

C

A

U

T

I

O

N

DISCON NEC T
A .C.  PO WER

AND
BATTER Y
BEFOR E

S ER VICING

D IS

CO

NN

EC

T

A .C

. P

OW

ER

A N

D

B A

T TE

RY

B E

F O

RE

SER V

IC

I N

G

Addressable devices

Audio NAC

Fire Alarm Local Mode Controller

ENABLE

CONTROL

Alarm

Alarm

Silenced

Local
Mode
Active

Power

On

Alarm
Silence

Reset

Local
Mode
Control

Local mode
controller

Strobe NAC

MINIPLEX transponder

Typical 4100U MINIPLEX System One-Line Drawing 

Introduction

4100U MINIPLEX transponders

 connect to a host 

4100U Fire Alarm Control Panel using Simplex

®

 remote 

unit interface (RUI) communications. At the transponder, 
RUI communications are received by the transponder 
interface module and translated into the same internal 
communications format that is used in the host control 
panel.  

Remotely located modules.

 With RUI 

communications, the transponder can remotely provide 
the same initiating and notification functions that occur at 
the host control panel without requiring multiple long 
distance wiring runs. Connections to the host panel are 
low current communications and audio wiring with 
distances up to 2500 ft (762 m). 

Software Revisions.

 Some of the features detailed and 

products listed in this document require 4100U System 
Software Revision 11.08 or higher. For pre-11.08 system 
expansion options, hardware updates may be required. 
Contact your local Simplex

®

 product supplier for details. 

**  Simplex fire alarm technology is protected by the following U.S. Patent Numbers: 

TrueAlarm analog smoke detection: 5,155,468; 5,173,683 and 5,543,777. IDNet and 
MAPNET II addressable communications; 4,796,025. TrueAlert addressable notification; 
6,313,744 and 6,426,697. SmartSync horn/strobe control; 6,281,789. Flex-35 and Flex-50 
amplifier operation; 6,452,491.

Fire Control Panels

UL, ULC Listed; FM, CSFM,

 Addressable Fire Detection and Control

and MEA (NYC) Approved*

 MINIPLEX

®

 Transponders

S4100-0035-6  4/2005

Summary of Contents for MINIPLEX 4100-9600

Page 1: ...n Off Auto PressACKlocatedunderflashingindicator Repeat operationuntil allevents areacknowledged Localtonew ill silence AB C AC Pow er D E F G H I J K L M N O P Q R SP 0 S T U VW X Y Z ALARMS F ire Al...

Page 2: ...sensors will alarm at a fixed temperature of 135 F 57 C x TrueAlarm device LEDs will be activated to indicate a device in alarm Local Mode Control Operation Continued Notification Operation Fire alar...

Page 3: ...ashing Tone On Press Ala rmSilence How to Reset System Press Sy stemReset Press Ack tosilence tone device ZONE 1 SIG 2 AUX 3 FB 4 IO 5 IDNet 6 P 7 A 8 L 9 NET ADDR 0 DEL Enter C Exit Fire Alarm Ack Pr...

Page 4: ...UL System Power Supply SPS 9 A power supply charger with 250 point IDNet channel 3 Class A B NACs and expansion slot for City Circuit or Alarm Relay option Canadian model has low battery cutout 4 Blo...

Page 5: ...Model Output Voltage 25 VRMS 70 7 VRMS Power Supply Input Listing Description Details 4100 1328 4100 1329 120 VAC 60 Hz UL 4100 1330 4100 1331 120 VAC 60 Hz ULC 4100 1332 4100 1333 220 230 240 VAC 50...

Page 6: ...102 MAPNET II Module 127 point capacity add devices separately Module size 2 Slots Loading per MAPNET II device 1 7 mA Fully loaded module total 470 mA 490 mA 4100 3103 Isolator Module for MAPNET II o...

Page 7: ...20 ft 6 1 m 2 Nine wires required 24 VDC 2 one per LED indicator 4 and one per switch 3 3 Wire size 18 AWG 0 82 mm Expansion Bay Module Loading Reference Description Mounting Transponder Interface Mo...

Page 8: ...r semi flush mounting 6 stud Optional semi flush trim kit reference Front view box outline without door Side view with door attached 2 Bay height 40 1016 mm Doors can be hinged left or right 3 Bay hei...

Reviews: