6. Set the Sig/Noise toggle switch to
Noise
(interfer-
ence signal measurement).
7. Hold the handset with its arm extended next to the
LockNode locking device.
8. Press the Activate button.
9
Interference signal strength is measured and
displayed (see table).
Signal strength
Connection can
be used (3060)
Connection can
be used
(SmartIntego)
100%-80%
Optimal
Yes
Yes
70%
Sufficient
Yes
Yes
60%
Sufficient
Yes
No
50%-40%
Sufficient
Yes
No
30%-10%
Too weak
No
No
No display
No connection
No
No
Data packet
transmission
Connection can
be used (3060)
Connection can
be used
(SmartIntego)
100%-80%
Good
Yes
Yes
70%-10%
Poor
No
No
No display
No connection
No
No
Interference sig-
nal strength
Connection can
be used (3060)
Connection can
be used
(SmartIntego)
No display
No interference
signal
Yes
Yes