Operating Instructions for the Palm LDB Version 1.40
14
Version: June 2004
6.9
Replacing a Digital Locking
When you replace a locking that cannot be reset, the software cannot program
the new locking at first. First you have to reset this locking in the locking plan:
Select the appropriate locking and touch
Details
. In the menu bar, select
Locking properties Data
. Then enter the locking system password.
☺
You can also use the Palm (m5xx, Tungsten W and Tungsten T3) in
combination with the PalmCD2 to verify the locking system password with
the password transponder. Do this by touching the appropriate button.
The PalmLDB now shows the
Target
and
Actual
values for the locking. Reset both
Target
values
to "Zero" by touching the appropriate number.
Delete this and replace the number with a
0
(zero). Touch the
Password
button. Enter 0x0
(zero, small x, zero) as the password. Touch
Accept. Then you can program the new locking
with the same description.
You do not have to perform these steps if you
can reset the cylinder that you want to replace
("old"). After the reset, you can program the
new locking cylinder immediately.