3 Disconnect the hydraulic connections of the
pump:
• From the flowmeter, disconnect the
Teflon pipe “B”.
4
Disconnect the electrical connections of the
pump using the tweezers:
A
:
temperature probe.
B
:
power supply.
5
Take the pump out of the machine.
• From the pump to the heater, unscrew
the fitting “C” using a 13 mm spanner.
B
Fig . 79
B
A
Fig . 81
Fig . 80
Flowmeter
Heater
NOTE
NOTE
Check the water inlet filter situated in the
heater connection and replace it, if necessary .
when replacing the pump, replace the O-ring
code No . 02280007 .V, too (see tables at the
end of the manual) .
Ed. 01 of 12/2015
6.3
Service Manual
Summary of Contents for MUSICA
Page 1: ...SERVICE MANUAL...
Page 2: ...Edition Date Modifications 01 12 2015 First Edition Ed 01 of 12 2015 II Service Manual...
Page 4: ......
Page 6: ...Ed 01 of 12 2015 IV Service Manual...
Page 38: ...Ed 01 of 12 2015 4 6 Service Manual...
Page 64: ...Ed 01 of 12 2015 6 18 Service Manual...
Page 76: ...Ed 01 of 12 2015 8 10 Service Manual...
Page 86: ...Ed 01 of 12 2015 10 6 Service Manual...
Page 98: ...Ed 01 of 12 2015 11 12 Service Manual...
Page 99: ......