User manual - METER SRT-457
Register
Write
Range
Register description
3Dh
Yes
0 ÷ 1
unit
parameter in
rEL2
menu:
0
- seconds;
1
- minutes
3Eh
Yes
0 ÷ 2
AL
parameter in
rEL2
menu:
0
- no changes;
1
- on;
2
- off
3Fh
Yes
-999 ÷ 9999
SEt2
parameter in
rEL2
menu, no decimal point included
40h
Yes
-999 ÷ 9999
SEtP
parameter in
rEL3
menu, no decimal point included
41h
Yes
-999 ÷ 999
HySt
parameter in
rEL3
menu, no decimal point included
42h
Yes
0 ÷ 5
modE
parameter in
rEL3
menu:
0
-
noAC
mode;
1
-
on
mode;
2
-
oFF
mode;
3
-
in
mode;
4
-
out
mode;
5
-
modb
mode
43h
Yes
0 ÷ 999
t on
parameter in
rEL3
menu, expressed in tenth of seconds or
tenth of minutes depend on
unit
parameter - register no. 45h)
44h
Yes
0 ÷ 999
toFF
parameter in
rEL3
menu, expressed in tenth of seconds
or tenth of minutes depend on
unit
parameter - register no. 45h)
45h
Yes
0 ÷ 1
unit
parameter in
rEL3
menu:
0
- seconds;
1
- minutes
46h
Yes
0 ÷ 2
AL
parameter in
rEL3
menu:
0
- no changes;
1
- on;
2
- off
47h
Yes
-999 ÷ 9999
SEt2
parameter in
rEL3
menu, no decimal point included
48h
Yes
-999 ÷ 9999
SEtP
parameter in
rEL4
menu, no decimal point included
49h
Yes
-999 ÷ 999
HySt
parameter in
rEL4
menu, no decimal point included
4Ah
Yes
0 ÷ 5
modE
parameter in
rEL4
menu:
0
-
noAC
mode;
1
-
on
mode;
2
-
oFF
mode;
3
-
in
mode;
4
-
out
mode;
5
-
modb
mode
4Bh
Yes
0 ÷ 999
t on
parameter in
rEL4
menu, expressed in tenth of seconds or
tenth of minutes depend on
unit
parameter - register no. 4Dh)
4Ch
Yes
0 ÷ 999
toFF
parameter in
rEL4
menu, expressed in tenth of seconds
or tenth of minutes depend on
unit
parameter - register no. 4Dh)
4Dh
Yes
0 ÷ 1
unit
parameter in
rEL4
menu:
0
- seconds;
1
- minutes
4Eh
Yes
0 ÷ 2
AL
parameter in
rEL4
menu:
0
- no changes;
1
- on;
2
- off
4Fh
Yes
-999 ÷ 9999
SEt2
parameter in
rEL4
menu, no decimal point included
50h
Yes
0 ÷ 1
modE
parameter in
HOLd
menu (type of detected changes):
0
- peaks;
1
- drops
51h
Yes
0 ÷ 9999
PEA
parameter in
HOLd
menu (minimum detectable change, no
decimal point included)
52h
Yes
0 ÷ 199
timE
parameter in
HOLd
menu,
maximum peaks' (or drops')
display time expressed in seconds
53h
Yes
0 ÷ 1
HdiS
parameter in
HOLd
menu:
0
-
rEAL
mode ;
1
-
HOLd
mode
54h
Yes
0 ÷ 1
H r1
parameter in
HOLd
menu
:
0
-
rEAL
mode ;
1
-
HOLd
mode