User manual - METER SRP-N118
Current input resistance
< 65
Ω
(typical 55
Ω
)
Voltage input
0÷5 V, 1÷5 V, 0÷10 V, 2÷10 V
Voltage measurement accuracy
± 0,1% @ 25°C; ± one digit (for 0÷10 V range)
Voltage input resistance
> 50 k
Ω
Temperature stability
50 ppm / °C
Display range
-999 ÷ 9999, plus decimal point
Accepted prolonged input overload: 20%
Outputs
relay:
or OC-type:
sensor power supply
U
O
:
0 or 2 NO, 1A/250V AC (cos
ϕ
= 1)
0 or 2; 30mA / 30VDC / 100mW
not stabilized
, not separated from measuring inputs,
in 230V AC and 110V AC and 24V AC version:
U
O
= 24V DC ± 3V / max. 25 mA;
in 24V DC version:
U
O
= U
S
/ max. 100 mA, R
O
= 3
0
Ω
,
(where U
S
- device power supply, R
O
- internal
resistance for sensor power supply output);
Communication interface
RS 485, 8N1 and 8N2, Modbus RTU,
not separated
Baud rate
1200 bit/s ÷ 115200 bit/s
Display
(depending on version)
LED, 4 digit, 20mm height, red or
LED, 4 digit, 20mm height, green
Data memory
non-volatile memory, EEPROM type
Protection level
IP 65
Housing type
Housing material
Housing dimensions
without glands
:
with glands:
wall mounted
ABS +
fibreglass
110 x 80 x 67 mm
110 x 105 x 67 mm
Operating temperature
(depending on version)
0°C to +50°C
or -20°C to +50°C
Storage temperature
(depending on version)
-10°C to +70°C
or -20°C to +70°C
Humidity
Altitude
5 to 90% no condensation
up to 2000 meters above sea level
Screws tightening max. torque
0,5 Nm
Max. connection leads diameter
2,5 mm
2
Safety requirements
according to: PN-EN 61010-1
installation category: II
pollution degree: 2
voltage in relation to ground: 300V AC
5
Summary of Contents for SRP-N118
Page 51: ...User manual METER SRP N118 51...