a) for the cylindrical tank in the vertical position:
„t h1”
- the height of the bottom part of a tank (in the elliptic paraboloid shape), this
parameter has the fixed precision - 2-decimal point,
„t h2”
- the height of the middle part of a tank in the cylindrical shape, this parameter has
the fixed precision - 2-decimal point,
„t h3”
- the height of the top part of a tank (in the elliptic paraboloid shape), this parameter
has the fixed precision - 2-decimal point,
„t d”
- the diameter of the middle part of a tank, this parameter has the fixed precision -
- 2-decimal point,
b) for the cylindrical tank in the horizontal position:
„t h1”
- the length of the left bottom of a tank (in the elliptic paraboloid shape), this
parameter has the fixed precision - 2-decimal point,
„t h2”
- the length of the middle part of a tank in the cylindrical shape, this parameter has
the fixed precision - 2-decimal point,
„t h3”
- the length of the right bottom of a tank (in the elliptic paraboloid shape), this
parameter has the fixed precision - 2-decimal point,
„t d”
- the diameter of the middle part of a tank, this parameter has the fixed precision -
- 2-decimal point,
„t Sn”
,
„t Sh”
- parameters defining the length and position of the sensor used to measure
level of liquids, gases or solids in the tank (Figure 7.1, 7.2).
„t Sn”
- distance between end of the sensor and bottom of the tank, this parameter has
the fixed precision 2-decimal point but the unit is 100 times smaller than “
t Sh
”
(see Info below),
„t Sh”
- the measuring range, this parameter has the fixed precision - 2-decimal point.
•
The unit value of “
t Sn
” parameter is 100-fold less than the unit value of
other parameters defining cylindrical tank, i.e. if we set value 10.00 in
“
t Sh
” parameter and set value 08.00 in "
t Sn
" parameter this mean that
value of “
t Sn
” parameter is real has 00.08 value in preserved unit of the
“
t Sh
” parameter.
•
If we set parameters of tank in [
m
] unit (“
t Sn
” parameter takes [
cm
] unit
respectively, see above), than displays the result the volume of the tank in
[
m
3
] unit, if we set parameters of tank in [
cm
] unit (“
t Sn
” parameter takes
[
mm
] unit respectively, see above), than displays the result the volume of
the tank in [
cm
3
] unit.
•
"
t Sh
" parameter may be greater than height (for vertical position) or
diameter (for horizontal position) of the tank, which means that the total
26