Active voltage output
(optional, for two relays or two
OC-type output version only)
range max. 0 ÷ 11V
Load resistance min.
2000
Ω
Temperature stability
50 ppm / °C
Display range
-999 ÷ 9999, plus decimal point
Communication interface
RS 485, 8N1 and 8N2, Modbus RTU,
not separated
Baud rate
1200 bit/s ÷ 115200 bit/s
Display
(depending on version)
LED, 4 digit, 38mm height, red or
LED, 4 digit, 38mm height, green
Data memory
non-volatile memory, EEPROM type
Front panel protection
IP 65
optional version with panel cut-out sealing available
Terminals protection
IP 20
Housing type
Housing material
Housing dimensions
Mounting hole
Assembly depth
Panel thickness
panel
NORYL - GFN2S E1
144 x 72 x 100 mm
138.5 x 67 mm
102 mm
max. 5 mm
Operating temperature
(depending on version)
0°C to +50°C
or -20°C to +50°C
Storage temperature
(depending on version)
-10°C to +70°C
or -20°C to +70°C
Humidity
Altitude
5 to 90% no condensation
up to 2000 meters above sea level
Screws tightening max. torque
0,5 Nm
Max. connection leads cross section 2,5 mm
2
Safety requirements
according to: PN-EN 61010-1
installation category: II
pollution degree: 2
voltage in relation to ground: 300V AC
insulation resistance
: >20M
Ω
insulation strength between power supply and
input/output terminal: 1min. @ 2300V
insulation strength between relays terminal:
1min. @ 1350V
EMC
according to: PN-EN 61326-1
6