The change of adjuster value during realisation of counting cycle do not change the
threshold stored while initialisation of the cycle. Storing of the new value is done
while initialisation of the new cycle (automatic or manual).
If
AUTORESET
function is active (parameter ”
Ar
” = ”
on
”), next cycle starts automatically with
delay ”
dLy
” (see description of parameter
”dLy”
) after counter reach previously stored
threshold of relay
R1
(”
Pr1
” or ”
000
”, depend on selected direction).
The change of parameters (except
„Pr1”
) causes that next cycle must be initialised
by user (even if
AUTORESET
function is active).
During delay device counts pulses, and LED „
F
” flashes signalling realisation of delay. If
AUTORESET
function is inactive, next cycle must be initialised by user using
[ESC/RESET]
button, by control input
clear/start
marked
{ D }
, or by writing of internal registers via RS-485
interface.
While power off, device stores its current counter value and restores it it after power
on. The state of counting and relays controlling cycles is not restored, it must be
initialised manually after power on (even if
AUTORESET
is active).
All accessible parameters can be changed by entering the menu (see:
DEVICE
PROGRAMMING
). Use the local keyboard or the remote controller to do it. (Note: all
parameters can be remote changed via RS-485 interface).
Configuration of the device (via menu or RS 485 interface)