![Simex SLN-94 User Manual Download Page 11](http://html1.mh-extra.com/html/simex/sln-94/sln-94_user-manual_1275350011.webp)
User manual - COUNTER SLN-94
Figure 4.6. Terminals description (relay outputs)
Description of control signals' symbols.
{ A }
-
counting input
, pulse;
{ B }
- hold
counting input
;
{ C }
-
stop counting input
;
{ D }
- reset counter input and start new counting cycle;
{ COM }
-
common terminal.
Figure 4.7. Terminals description (OC-type outputs)
11
1
2
5 6 7 8 9
GND
DATA+
DATA-
RS - 485
+
Uo
-
+24V
+5%, -10%
I
max = 100mA
10 11 12 13
R1
R2
D
COM
B
A
C
14 15
Power
supply
(depending on version)
n.c.
n.c.
16
31
17
32
18
33
19
34
20
35
1
2
5 6 7 8 9
GND
DATA+
DATA-
RS - 485
+
Uo
-
+24V
+5%, -10%
I
max = 100mA
10 11 12 13 14 15
OC1
OC2
D COM
B
A
- + + -
C
OC1 ÷ OC2:
U
max = 30V DC,
I
max = 30mA,
P
max = 100mW
Power
supply
(depending on version)
n.c.
n.c.
16
31
17
32
18
33
19
34
20
35