Summary of Contents for SLM-44

Page 1: ...2 24V DC or 100 240V AC Read the user s manual carefully before starting to use the unit or software Please keep this manual for future reference Producer reserves the right to implement changes witho...

Page 2: ...t time 17 7 2 4 Operation mode 18 7 2 5 Prescale 19 7 2 6 Decimal Point Position 19 7 2 7 Write 20 7 2 8 Key protect 20 8 OPERATION MODE AND OUTPUT MODE 21 8 1 OPERATION MODE A 21 8 2 OPERATION MODE B...

Page 3: ...ion of troubleshooting in the case of malfunction Neighbouring and mating equipment must meet the requirements of appropriate standards and regulations concerning safety and be equipped with adequate...

Page 4: ...to 10 kHz input signal contact open collector or voltage prescale decimal point position key protection and free write It has a built in EEPROM memory to avoid loss of count during sudden power cut Th...

Page 5: ...r can be requested to use appropriate preventive measures 4 DEVICE INSTALLATION The unit has been designed and manufactured in a way assuring a high level of user safety and resistance to interference...

Page 6: ...o starting assembly Check the correctness of the performed connections prior to switching the unit on In order to assembly the unit a 45 x 45 mm mounting hole Figure 4 1 must be prepared Place the uni...

Page 7: ...switched on because it carries the risk of electrical shock Due to possible significant interference in industrial installations appropriate measures assuring correct operation of the unit must be app...

Page 8: ...vidual add and subtract input 2 inputs a Contact input b Open collector input c Voltage input Figure 4 6 Connection of 90 quadrature input 2 inputs 8 OUT 1 COM N O OUT 2 COM N O N C RES 12V IN B IN A...

Page 9: ...mponents and shorten the fault free time of unit operation In cases where the unit gets dirty do not clean with solvents For cleaning use warm water with small amount of detergent or in the case of mo...

Page 10: ...r to Program Mode press and hold by at least 2 sec exit the current level and enter to previous menu or to Run Mode change of the individual counter modes Description of program item display IN Hz Cou...

Page 11: ...tor must press and hold at least 2 sec MODE button Wait for 2 seconds to return to the Run Mode 7 DEVICE PROGRAMMING The setting of the SLN 44 unit is configured using the DIP switch and the Program M...

Page 12: ...1 1 DP1 Input type Counter SLN 44 is equipped with one measuring input The are following types to be selected Contact for low speed signals Open collector Voltage high speed 12 INPUT MODE COUNT SPEED...

Page 13: ...1kHz 7 1 3 DP3 Count mode During normal operation the counter counts pulses from input A and B according to selected count mode Figure 7 2 calculates using prescale value and shows the result on main...

Page 14: ...functionality of DP4 and DP5 7 1 4 DP7 Reset time Reset time sets minimum pulse time of remote reset signal If an active signal is delivered to the rear terminals 4 and 5 the counter is zeroed and th...

Page 15: ...uttons device exits the Program Mode and returns to the Run Mode only if no parameters are in editing mode Press individual digit setting keys to change setting values The meaning of parameters is des...

Page 16: ...set One Shot 10 9990 ms Hold Hold1 Hold2 Equal Output Output occurs only when and continues as long as count value is equal to preset value Lower Limit Output Output occurs when count value reaches be...

Page 17: ...Preset Hold 2 Output is Latched until a Reset signal is sent independent from Output 2 One Shot Output time can be set from 10 9990 ms at 10 ms steps All Models for all standard output Output time pr...

Page 18: ...unt during and after output signal duration Mode D Unit resets at rising edge of output signal Auto Reset Mode E Unit resets at falling edge of output signal For One Shot Output time only Mode F Unit...

Page 19: ...t per 10 pulses PS value 0 1 2 To display 1 count per 5 pulses PS value 0 2 3 To display 2 counts per 1 pulse PS value 2 Prescale programming Program Item Display Setting Values Setting Key Default Va...

Page 20: ...n every reset the set value will be displayed Default setting is 0 Write programming Program Item Display Setting Values Setting Key Default Value W Press corresponding numeric keys 7 2 8 Key protect...

Page 21: ...te of particular relay output One of the following operation modes and output modes OUT can be selected 8 1 OPERATION MODE A a Standard output mode b Equal output mode c Upper and lower limit outputs...

Page 22: ...ignal duration 8 3 OPERATION MODE C Standard output mode Unit does not count during and after output signal duration 22 In case of 1 level preset models operation is the same as OUT 1 operation HOLD2...

Page 23: ...ut mode Auto reset at rising edge of output OUT2 8 5 OPERATION MODE E Standard output mode Auto reset at falling edge of output OUT2 23 In case of 1 level preset models operation is the same as OUT 2...

Page 24: ...reset at falling edge of output display frozen during output 24 one shot or HOLD1 one shot HOLD2 one shot one shot or HOLD1 one shot HOLD2 one shot In case of 1 level preset models operation is the sa...

Page 25: ...User manual for electronic preset counter SLN 44 25...

Page 26: ...User manual for electronic preset counter SLN 44 26...

Page 27: ...User manual for electronic preset counter SLN 44 27...

Page 28: ...Microlectra bv Augustapolder 12 2992 SR Barendrecht The Netherlands www microlectra nl info microlectra nl...