User manual for electronic preset counter SLN-44
Attached with the unit please find:
- user’s manual,
- accessories (gasket, clip and terminal cover).
4.2.
ASSEMBLY
- The unit is designed for mounting indoor inside housings (control panel,
switchboard) assuring appropriate protection against electric impulse waves.
Metal housing must be connected to the grounding in a way complying with the
governing regulations.
- Disconnect the power supply prior to starting assembly.
- Check the correctness of the performed connections prior to switching the unit on.
In order to assembly the unit, a 45 x 45 mm mounting hole (Figure 4.1) must be
prepared. Place the unit in the mounting hole inserting it from the front side of the
panel, then install the clip into the rear of the counter, push forward and clamp into
place while holding the counter firmly against the direction of the clip. The
dimension of the clip is 47.5 x 60.5 mm.
Figure 4.1. Panel cut-out dimensions
Figure 4.2. Dimensions of the case and installing of clip, gasket and terminal cover.
6
45 mm
+0,6
4
5
m
m
+
0,
6
6.2
99.8
6.2
63.8
44
.5
44
.5