The output time will automatically become
if the
output mode is different than
If DP6 is ON (see:
7.1 DIP SWITCH SETTINGS
, str.12),
"
Count Speed
" is not displayed.
Key 1 will
select the
desired value
7.2.4.
Operation mode
There are 7 Operation Modes available in counters
SLN-44
. The output below refers to
the 1 Level Preset model, OUT2 of 2 Level Preset Model.
Default setting is Mode A.
Mode A
Unit counts during output signal duration
Overrun
(Without Auto-Reset)
Mode B
Unit does not count during output signal duration
Mode C
Unit does not count during and after output signal
duration
Mode D
Unit resets at rising edge of output signal
Auto-Reset
Mode E
Unit resets at falling edge of output signal (For One-
Shot Output time only)
Mode F
Unit resets at rising edge of output signal, unit display
frozen during output signal duration (For One-Shot
Output time only)
Mode G
Unit resets at falling edge of output signal, unit display
frozen during output signal duration (For One-Shot
Output time only)
For 24V DC power supply all operation modes refer to output OUT.
Operation mode programming:
Program
Item
Display
Setting Values
Setting Key
Default
Value
Only mode A can be set if the output mode is
different than
. Mode E, F, G, can only be set if
OUT or OUT 2 is programmed to one shot output.
Key 1 will select
the desired
value
(Mode A)