For parts or assistance, call Simer Customer Service at 1-800-468-7867

Troubleshooting  

5

 Sudden Starts. If the power is on to the pump when thermal overload resets, the pump may start without warning. 

If you are working on the pump, you may get an electrical shock or the impeller may catch fingers or tools. Disconnect the power 

before servicing the pump.

A. Pump fails to operate:

1. Check to be sure that power cord is securely plugged into outlet or securely wired into controller or switch 

box. Disconnect power to outlet before handling pump or motor.

2. Check to be sure you have electrical power.
3. Check that liquid fluid level is high enough to activate switch or controller.
4. Check to be sure that the anti-airlock vent hole in the pump discharge is not plugged.
5. Check for blockage in pump inlet, impeller, check valve or discharge pipe.
6. Disconnect the pump from the power source for a minimum of 30 minutes to allow the motor to cool and to 

protect yourself from sudden starts. See Warning above. 
Check for the cause of overheating. Pump is running dry because the float switch is caught up on something. 
Inlet pipe is plugged. Outlet pipe is plugged.

B. Pump fails to empty sump:

1. Be sure all valves in discharge pipe are fully open.
2. Clean out discharge pipe and check valve.
3. Check for blockage in pump inlet or impeller.
4. Pump not sized properly. A higher capacity pump may be required.

C. Pump will not shut off:

1. Check switch or controller automatic floats for proper operation and location.  

 See installation instructions for switch/controller.

2. If pump is completely inoperative or continues to malfunction, consult your local serviceman.

Summary of Contents for 3963C

Page 1: ...cording to local codes 8 Do not install the basin or pump in any location classified as hazardous by the United States National Electrical Code NEC or by the Canadian Electrical Code CEC where applica...

Page 2: ...l codes that apply Explosion hazard Improper ventilation of sewer gases can result in leakage of methane sewer gas and a possible explosion of fumes resulting in severe injury or death Vent basin acco...

Page 3: ...rical power to the pump and the control switch Do not lift the pump by the power cord See the Cord Lift Warning below NOTICE Always wear gloves when handling the pump for service or maintenance NOTICE...

Page 4: ...Bolt 8 7 Washer 8 8 Sewage Basin Cover 1 PW73 48 9 Gasket Tape Cover 1 10 Sewage Basin 1 PW73 46 11 Inlet Hub Snap In 1 12 Sewage Pump 1 3963 13 Discharge Pipe 1 U78 996P Hardware Package 1 Incl Key N...

Page 5: ...t hole in the pump discharge is not plugged 5 Check for blockage in pump inlet impeller check valve or discharge pipe 6 Disconnect the pump from the power source for a minimum of 30 minutes to allow t...

Page 6: ...handling the pump For warranty purposes return the pump s cord tag and original receipt of purchase to the retail store Dispose of the pump according to local disposal ordinances Exceptions to the Tw...

Page 7: ...t pas n cessaire de la huiler ni de la graisser Si la pompe doit tre r vis e se reporter aux instructions figurant sous la rubrique Entretien 7 Pr voir une mise l air libre ad quate du r servoir des e...

Page 8: ...phase indiqu es sur la plaque signal tique du moteur de la pompe correspondent exactement au courant d alimentation Installer la pompe conform ment aux codes de l lectricit en vigueur Risque d explos...

Page 9: ...lifi Aucune pi ce de cette pompe n est r parable par une personne non qualifi e Apr s avoir enlev le couvercle du bassin et d branch toute la tuyauterie de refoulement n cessaire sortir la pompe du ba...

Page 10: ...D signation des pi ces Qt 3963C 1 Clapet de non retour en PVC de 2 po battant 1 PW73 49 2 Bague d tanch it en caoutchouc pour le passage du tuyau de refoulement 2 po 1 3 Joint torique taille droite 2...

Page 11: ...e mise l air libre antibouchon d air du refoulement de la pompe n est pas bouch 5 S assurer que l admission de la pompe l impulseur le clapet de non retour ou le tuyau de refoulement ne sont pas bouch...

Page 12: ...la pompe des fins de garantie retourner l tiquette figurant sur le cordon de la pompe et l original du re u au d taillant Mettre la pompe au rebut conform ment la r glementation locale Exceptions la...

Page 13: ...grasa bajo una operaci n normal Consulte las instrucciones en la secci n de Servicio para la puesta a punto 7 Ventile el tanque s ptico o de aguas residuales conforme con los c digos locales 8 No inst...

Page 14: ...rada Instale la bomba conforme con todos los c digos el ctricos que correspondan Peligro de explosi n Una ventilaci n inadecuada de los gases del sumidero puede resultar en fugas de gas metano del sum...

Page 15: ...l capacitado La bomba no contiene piezas de consumo que se puedan reparar Despu s de sacar la cubierta del dep sito y la tuber a de descarga necesaria levante y saque la bomba del dep sito Coloque la...

Page 16: ...e No Descripci n de la pieza Cant 3963C 1 V lvula de retenci n PVC oscilante de 2 1 PW73 49 2 Aro de refuerzo de descarga 2 1 3 Aro t rico de corte cuadrado 2 4 Aro de refuerzo del cord n 1 5 Aro de r...

Page 17: ...carga de la bomba no est obturado 5 Verifique que la admisi n de la bomba el impulsor la v lvula de retenci n o la tuber a de descarga no est n bloqueados 6 Desconecte la bomba de la fuente de corrien...

Page 18: ...ci n Si su bomba cloacal ha fallado Use guantes de caucho cuando manipule la bomba Para los fines de la garant a devuelva la etiqueta del cord n de la bomba y el recibo de compra original a la tienda...

Page 19: ...Para refacciones o asistencia llame a Simer Servicios al Cliente al 1 800 468 7867 19...

Page 20: ......

Reviews: