background image

Safety  

2

For parts or assistance, call Simer Customer Service at 

800-468-7867 / 800-546-7867

Important Safety Instructions

SAVE THESE INSTRUCTIONS - This manual contains important 
instructions that should be followed during installation, 
operation, and maintenance of the product. 

 This is the 

safety alert symbol. When you see this symbol on your pump 
or in this manual, look for one of the following signal words 
and be alert to the potential for personal injury!

 indicates a hazard which, if not avoided, will 

result in death or serious injury.

 indicates a hazard which, if not avoided, could 

result in death or serious injury.

 indicates a hazard which, if not avoided, could 

result in minor or moderate injury.
NOTICE addresses practices not related to personal injury.
Carefully read and follow all safety instructions in this manual 
and on pump.
Keep safety labels in good condition. Replace missing or 
damaged safety labels.
California Proposition 65 Warning

 This product and related accessories contain 

chemicals known to the State of California to cause cancer, 
birth defects or other reproductive harm.
1.  Know the pump application, limitations, and potential  

hazards. Pump water only with this pump.

2.  Do not use this pump in water with fish present. If any oil 

leaks out of the motor it can kill fish.

3.  Disconnect the power before servicing.
4.  Release all pressure within the system before servicing any 

component.

5.  Drain all the water from the system before servicing.
6.  Secure the discharge line before starting the pump. An 

unsecured discharge line will whip, possibly causing 

personal injury and/or property damage.

7.  Check hoses for weak or worn condition before each use, 

making certain that all connections are secure.

8.  Periodically inspect the sump, pump and system 

components. Keep free of debris and foreign objects. Perform 

routine maintenance as required. 

9.  Provide a means of pressure relief for pumps whose 

discharge line can be shut-off or obstructed.

10. Personal Safety:

a.  Wear safety glasses at all times when working with 

pumps.

b.  Keep work area clean, uncluttered and properly lighted – 

replace all unused tools and equipment.

c.  Keep visitors at a safe distance from work area.
d.  Make workshop child-proof – with padlocks, master 

switches, and by removing starter keys.

11. When wiring an electrically driven pump, follow all 

electrical and safety codes that apply.

12. This equipment is only for use on 115 volt and is equipped 

with an approved 3-conductor cord and 3-prong, grounding-

type plug.

 

 Risk of electric shock. Can shock, burn or 

kill. To reduce the risk of electric shock, pull the plug 

before servicing. Pump is supplied with a grounding 

conductor and grounding-type attachment plug. Be sure it 

is connected only to a properly grounded grounding-type 

receptacle.

 

 

Where a 2-prong wall receptacle is encountered, it must 

be replaced with a properly grounded 3-prong receptacle 

installed in accordance with codes and ordinances that apply. 

 

This pump has not been investigated for use in swimming 

pool areas. 

13.  A ground fault circuit interrupter is recommended for use 

with any electrical appliance submerged in water. Installation 

and all wiring should be performed by a qualified electrician.

14. Make certain the power source conforms to the requirements 

of your equipment.

15. Protect the electrical cord from sharp objects, hot surfaces, 

oils, and chemicals. Avoid kinking the cord. Replace or repair 

damaged or worn cords immediately.

16. Do not touch an operating motor. Motors can operate at 

high temperatures.

17. Do not handle the pump or pump motor with wet hands or 

when standing on a wet or damp surface, or in water.

 Risk of electric shock. Can shock, burn or kill. If 

your basement has water or moisture on floor, do not walk on 

the wet area until all power has been turned off. If the shut-off 

box is in the basement, call electric company or hydro authority 

to shut-off the service to house, or call your local fire department 

for instructions. Failure to follow this warning can result in fatal 

electrical shock. 
18. DO NOT splice the electrical power cord.
19. DO NOT allow the electrical cord plug to be submerged.
20. DO NOT use extension cords. They are a fire hazard and 

can reduce voltage sufficiently to prevent pumping and/or 

damage motor.

21. Connect or wire the pump to an individual branch circuit 

with no other outlets or equipment in the circuit. Size fuses 

or circuit breakers according to the specifications.

Specifications

Power supply required ........................................... 115V, 60 HZ
Liquid Temp. Range ............................... 32° F-120° F (0°-49° C)
Individual Branch Circuit Required............................... 15 Amps
Discharge Adapter .................................................1-1/4” MNPT

Pump water only with this pump.
NOTICE This unit is not designed as a waterfall or fountain 

pump, or for applications involving salt water or brine! Use with 

waterfalls, fountains, salt water or brine will void warranty.
Do not use where water recirculates.
Not designed for use as a swimming pool drainer.

Summary of Contents for 2905-04

Page 1: ... Français Pages 7 11 Instalación Operación Piezas Para mayor información sobre el funcionamiento instalación o mantenimiento de la bomba Llame al 800 468 7867 Español Paginas 12 16 2012 SIM860 07 20 12 OWNER S MANUAL Submersible Sump Pump NOTICE D UTILISATION Pompe de puisard submersible MANUAL DEL USUARIO Bomba sumergible de sumidero 5922 0109 5921 0109 2905 04 2955 04 2957 04 293 Wright Street D...

Page 2: ... safety codes that apply 12 This equipment is only for use on 115 volt and is equipped with an approved 3 conductor cord and 3 prong grounding type plug Risk of electric shock Can shock burn or kill To reduce the risk of electric shock pull the plug before servicing Pump is supplied with a grounding conductor and grounding type attachment plug Be sure it is connected only to a properly grounded gr...

Page 3: ...ion and requires a minimum 15 amp individual branch circuit Both the pump and switch are supplied with 3 wire cord sets with grounding type plugs The switch plug is inserted directly into the outlet and the pump plug inserts into the opposite end of switch plug Risk of electric shock Can shock burn or kill Pump is supplied with a grounding conductor and grounding type attachment plug To reduce the...

Page 4: ...e basin with water and observing the pump s operation through one complete cycle Risk of flooding Can cause personal injury and or property damage Failure to make this operational check can lead to improper operation premature pump failure and flooding To Replace the Vertical Float Switch NOTICE The float must be able to complete its entire cycle without interference from any other object 1 Mount ...

Page 5: ...ve float switch Replace float switch Restricted discharge Remove pump and clean pump and piping obstacle in piping Float obstructed Remove obstruction Pump operates but Low line voltage If voltage under recommended minimum check size of wiring from main delivers little or no water switch on property If OK contact power company or hydro authority Worn or plugged impeller Replace pump Anti airlock v...

Page 6: ...turn a sewage pump that has been installed to your retail store Contact SIMER Customer Service Sewage pumps that have seen service and been removed carry a contamination hazard with them If your sewage pump has failed Wear rubber gloves when handling the pump For warranty purposes return the pump s cord tag and original receipt of purchase to the retail store Dispose of the pump according to local...

Page 7: ... et de l électricité en vigueur 12 Cette pompe ne fonctionne que sur le courant alternatif de 115 volts et elle est équipée d un cordon électrique approuvé à 3 conducteurs muni d une fiche à 3 broches dont une de mise à la terre Risque de secousses électriques Pouvant causer des brúlures voire la mort Pour réduire les risques de secousses électriques débrancher la fiche du cordon électrique de la ...

Page 8: ...teurs eux mêmes munis d une fiche de mise à la terre La fiche de l interrupteur à flotteur se branche directement dans la prise de courant et la fiche de la pompe se branche à l arrière de la fiche de l interrupteur à flotteur Risque de secousses électriques Pouvant causer des brúlures voire la mort La pompe est livrée avec un conducteur et une fiche de mise à la terre Pour réduire les risques de ...

Page 9: ...fonctionnement de la pompe sur un cycle complet Risque d inondation Peut causer le mauvais fonctionnement ou une panne prématurée de la pompe Ne pas procéder à cette vérification de fonctionnement risque de causer un mauvais fonctionnement et une panne prématurée de la pompe ainsi qu une inondation Pour remplacer un interrupteur à flotteur vertical AVIS Le flotteur doit pouvoir se déplacer sur tou...

Page 10: ...e s arrête pas Interrupteur à flotteur défectueux Remplacer l interrupteur à flotteur Refoulement obstrué Déposer la pompe et la nettoyer ainsi que les tuyaux obstruction dans le tuyau Flotteur obstrué Enlever l obstruction La pompe fonctionne mais Tension de ligne basse Si la tension est inférieure à la tension minimum recommandée vérifier le ne débite pas d eau ou calibre des conducteurs côté in...

Page 11: ...vec le service à la clientèle de SIMER Les pompes d eaux d égout qui ont été utilisées puis retirées présentent un risque de contamination En cas de défaillance de la pompe d eaux d égout Porter des gants en caoutchouc pour manipuler la pompe À des fins de garantie retourner l étiquette figurant sur le cordon de la pompe et l original du reçu au détaillant Mettre la pompe au rebut conformément à l...

Page 12: ...ado de una bomba de accionamiento eléctrico cumpla con todos los códigos de electricidad y seguridad que correspondan 12 Este equipo se debe usar solamente con 115 voltios y viene equipado con un cordón aprobado de 3 conductores y un enchufe de 3 clavijas con conexión a tierra Riesgo de choque eléctrico Puede provocar choque quemadura o muerte Para reducir el peligro de choque eléctrico desenchufe...

Page 13: ... como el interruptor vienen con un juego de cordón trifilar y enchufe con puesta a tierra El enchufe del interruptor se inserta directamente en el tomacorriente y el enchufe de la bomba se inserta en el extremo opuesto del enchufe del interruptor Riesgo de choque eléctrico Puede provocar choque quemadura o muerte La bomba viene provista de un conductor de puesta a tierra y un enchufe de conexión a...

Page 14: ... durante un ciclo completo Riesgo de inundación Puede provocar lesiones personales y o daños materiales El no realizar esta inspección de funcionamiento puede resultar en un funcionamiento inadecuado una falla prematura e inundación Cómo reemplazar el interruptor de flotador vertical AVISO El flotador debe poder completar todo su ciclo sin interferencia de objeto alguno 1 Monte el soporte en la ca...

Page 15: ...fectuoso Reemplace el interruptor de flotador detiene con demasiada Descarga restringida Saque la bomba y limpie la bomba y la tubería frecuencia obstáculo en la tubería Flotador obstruido Elimine la obstrucción La bomba funciona pero Baja tensión de línea Si la tensión es inferior al mínimo recomendado verifique el tamaño de los descarga poco o nada cables desde el interruptor principal en la pro...

Page 16: ...devuelva una bomba cloacal que se haya instalado a su tienda minorista Comuníquese con el Departamento de Atención al Cliente de SIMER Las bombas cloacales que hayan estado en servicio y se hayan removido pueden representar un peligro de contaminación Si su bomba cloacal ha fallado Use guantes de caucho cuando manipule la bomba Para los fines de la garantía devuelva la etiqueta del cordón de la bo...

Reviews: