Warranty

5

For parts or assistance, call Simer Customer Service at 

1-800-468-7867 / 1-800-546-7867

ATTACH ORIGINAL RECEIPT HERE FOR WARRANTY CONSIDERATION.

SIMER 

w

arrants to the original cons

u

mer p

u

rchaser (“P

u

rchaser”) of its prod

u

cts that they are free from defects in material or 

w

orkmanship.

If 

w

ithin t

w

elve (12) months from the date of the original cons

u

mer p

u

rchase any s

u

ch prod

u

ct shall prove to 

b

e defective, it shall 

b

e repaired or

replaced at SIMER’s option, s

ub

ject to the terms and conditions set forth 

b

elo

w

. Yo

u

r original receipt of p

u

rchase is req

u

ired to determine 

w

arranty

eligi

b

ility.

Exceptions to the Twelve (12) Month Warranty

Product/Model No.

Warranty Period

M40P, M40, BW85P, CM10, CMK

90 days

2330, 2300, 2310, 2955, 2956, 2957, 2960, A5500

2 Years

4" S

ub

mersi

b

le Well P

u

mps, 3984, 3983, 2975PC, 2958, 2985, 3075SS

3 Years

Pre-Charge Water System Tank, 3986, 3985, 2956

5 Years

3988, 3995, 3997, 3963

Lifetime

General Terms and Conditions

P

u

rchaser m

u

st pay all la

b

or and shipping charges necessary to replace prod

u

ct covered 

b

y this 

w

arranty. This 

w

arranty shall not apply to

acts of God, nor shall it apply to prod

u

cts 

w

hich, in the sole j

u

dgement of SIMER, have 

b

een s

ub

ject to negligence, a

bu

se, accident, misap-

plication, tampering, alteration; nor d

u

e to improper installation, operation, maintenance or storage; nor to other than normal application, 

u

se

or service, incl

u

ding 

bu

t not limited to, operational fail

u

res ca

u

sed 

b

y corrosion, r

u

st or other foreign materials in the system, or operation at

press

u

res in excess of recommended maxim

u

ms.

Req

u

ests for service 

u

nder this 

w

arranty shall 

b

e made 

b

y ret

u

rning the defective prod

u

ct to the Retail o

u

tlet or to SIMER as soon as possi-

b

le after the discovery of any alleged defect. SIMER 

w

ill s

ub

seq

u

ently take corrective action as promptly as reasona

b

ly possi

b

le.

N

o

req

u

ests for service 

u

nder this 

w

arranty 

w

ill 

b

e accepted if received more than 30 days after the term of the 

w

arranty.

This 

w

arranty sets forth SIMER’s sole o

b

ligation and p

u

rchaser’s excl

u

sive remedy for defective prod

u

cts.

SIMER SHALL 

N

OT BE LIABLE FOR A

N

Y CO

N

SEQUE

N

TIAL, I

N

CIDE

N

TAL, OR CO

N

TI

N

GE

N

T DAMAGES WHATSOEVER.

THE FOREGOI

N

G WARRA

N

TIES ARE EXCLUSIVE A

N

D I

N

 LIEU OF ALL OTHER EXPRESS WARRA

N

TIES. IMPLIED WARRA

N

TIES,

I

N

CLUDI

N

G BUT 

N

OT LIMITED TO THE IMPLIED WARRA

N

TIES OF MERCHA

N

TABILITY A

N

D FIT

N

ESS FOR A PARTICULAR PUR-

POSE, SHALL 

N

OT EXTE

N

D BEYO

N

D THE DURATIO

N

 OF THE APPLICABLE EXPRESS WARRA

N

TIES PROVIDED HEREI

N

.

Some states do not allo

w

 the excl

u

sion or limitation of incidental or conseq

u

ential damages or limitations on ho

w

 long an implied 

w

arranty

lasts, so the a

b

ove limitations or excl

u

sions may not apply to yo

u

. This 

w

arranty gives yo

u

 specific legal rights and yo

u

 may also have other

rights 

w

hich vary from state to state.

SIMER • 293 Wright Street • Delavan, WI U.S.A. 53115

Phone: 1-800-468-7867/1-800-546-7867 • Fax: 1-800-390-5351

E-Mail: [email protected] • Web Site: http://www.simerpumps.com

Summary of Contents for 2115

Page 1: ...tance Call 1 800 468 7867 English Pages 2 5 Installation Fonctionnement Pièces Pour plus de renseignements concernant l utilisation l installation ou l entretien Composer le 1 800 468 7867 Français Pages 6 9 Instalación Operación Piezas Para mayor información sobre el funcionamiento instalación o mantenimiento de la bomba Llame al 1 800 468 7867 Español Paginas 10 13 2007 SIM822 Rev 12 10 07 MODEL...

Page 2: ... application backflow is a problem when the pump stops prevent it by installing a 1 NPT check valve in the pump discharge 4 Power Supply Pump is designed for 115V 60 HZ operation and requires an individual branch circuit of 15 amperes or more capacity It is supplied with a 3 wire cord set with grounding type GFCI protected plug for use in a 3 wire grounded outlet For safety pump should always be e...

Page 3: ...he motor will restart NOTICE If the overload protector stops the pump repeated ly disconnect the power from the pump and check it to find the problem Low voltage clogged impeller too much back pressure in the discharge hose as when pumping through 50 15 M of coiled hose or extended running of pump with no load can all cause overheating 2 The water being pumped cools the motor allowing the pump to ...

Page 4: ... motor fails replace entire pump Not Illustrated SYMPTOM POSSIBLE CAUSE S CORRECTIVE ACTION Pump won t Blown fuse If blown replace with fuse of proper size start or run Low line voltage If voltage under recommended minimum check size of wiring from main switch on property If OK contact power company Defective motor Replace pump Impeller Remove base and screen locate source of binding Pump operates...

Page 5: ... including but not limited to operational failures caused by corrosion rust or other foreign materials in the system or operation at pressures in excess of recommended maximums Requests for service under this warranty shall be made by returning the defective product to the Retail outlet or to SIMER as soon as possi ble after the discovery of any alleged defect SIMER will subsequently take correcti...

Page 6: ... que possible 3 Si en fonction de l utilisation le refoulement représente un problème lorsque la pompe s arrête poser un clapet antire tour de 1 pouce NPT côté refoulement de la pompe 4 Source d alimentation La pompe est conçue pour du 115V et 60HZ et requiert un circuit de dérivation individuel de 15 ampères ou plus Elle est fournie avec un cordon trifilaire et une fiche de type mise à la terre e...

Page 7: ...on répétitive débrancher la pompe et déterminer le problème Une basse tension un impulseur bouché une contre pression trop importante dans le tuyau de refoulement comme pomper de l eau dans un tuyau enroulé ayant jusqu à 50 pieds 15 mètres ou un fonctionnement prolongé à vide de la pompe causera une surchauffe 2 L eau pompée refroidit le moteur ce qui permet à la pompe de fonctionner continuelleme...

Page 8: ...té Le moteur est défectueux Remplacer la pompe Roue hélice Retirer la base et le filtre repérer la source de l obstruction La pompe La tension est faible Appeler la compagnie d électricité fonctionne mais Quelque chose obstrue Nettoyer la roue hélice elle déverse peu la roue hélice ou pas d eau Tuyau d arrosage de petit Utiliser un tuyau souple de 1 pouce ou un tuyau d arrosage de plus grand diamè...

Page 9: ...ausées par la corrosion la rouille ou autre corps étranger dans le système ou à des produits ayant fonctionné à des pressions dépassant la limite maximale recommandée Les demandes de service en vertu de la présente garantie seront faites en retournant le produit défectueux au détaillant ou à SIMER dès la dé couverte de tout défaut allégué SIMER prendra alors les mesures correctives aussi rapidemen...

Page 10: ...roflujo es un problema cuando la bomba se detiene evítelo instalando una válvula de reten ción de 1 NPT en la descarga de la bomba 4 Fuente de alimentación La bomba está diseñada para operar a 115V y 60 Hz y requiere un ramal individual de 15 amperes o más de capacidad Se suministra con un juego de cordón de 3 alambres con enchufe tipo conexión a tierra protegido por un disyuntor para ser utilizad...

Page 11: ...blema Tensiones bajas impulsores bloqueados demasiada presión en la manguera de descarga como en los casos en que se bombea a través de 50 pies 15 metros de manguera enredada o una operación prolongada de la bomba sin carga pueden causar recalentamiento 2 El agua que se bombea enfría el motor lo que permite que la bomba continúe funcionando a cualquier profundidad de agua por encima de 1 4 de pulg...

Page 12: ...a compañía eléctrica Motor defectuoso Reemplace la bomba Impulsor Saque la base y el filtro ubique la fuente de fijación La bomba Bajo voltaje de línea Llame a la compañía de electricidad funcionapero Objeto atascado en el rodete Limpie el impulsor no suministra Manguera de jardín de Use una manguera de jardín de mayor diámetro o un tubo flexible de 1 agua o muy diámetro chico o línea de Deseche e...

Page 13: ... incluyendo pero no limitado a fallas operacionales causadas por corrosión oxidación u otros elementos extraños en el sistema o funcionamiento a presión por encima del máximo recomendado Los pedidos de servicio bajo los términos de esta garantía serán efectuados mediante la devolución del producto defectuoso al Vendedor o a SIMER tan pronto como sea posible después de localizado cualquier supuesto...

Page 14: ...14 For parts or assistance call Simer Customer Service at 1 800 468 7867 1 800 546 7867 ...

Page 15: ...15 For parts or assistance call Simer Customer Service at 1 800 468 7867 1 800 546 7867 ...

Page 16: ......

Reviews: