Operation

3

OPERATION

Risk of electrical shock. Can burn or cause

death.

Do not handle pump or pump motor with wet hands or

when standing on wet or damp surface, or in water.
Disconnect power from pump before handling, servicing, or
attempting to repair pump.

NOTE:

The power cord for this pump is equipped with a

Ground Fault Circuit Interrupter (GFCI). The GFCI will shut
down the pump in the event of leakage of electrical current
from the pump motor or cord to ground. If the pump does not
respond when plugged in, unplug it, reset the GFCI (push the
RESET button on the plug) and plug it in again. If it still doesn’t
respond, make sure that the circuit breaker for the branch cir-
cuit is in the ‘on’ position (closed). if the circuit breaker is
closed and the pump doesn’t respond, consult a licensed elec-
trician. DO NOT TRY TO MODIFY the cord or plug, and do
not remove the GFCI.

The Electronic Pool Cover Pump is fully automatic in 
operation. The “smart” controller starts the pump every 
2-1/2 minutes and causes it to run for 5 seconds. If it senses
that there is no water to the pump, it stops. If it senses water, it
continues to run until the water is pumped down to 1/4" deep,
and then it stops. It then goes into a 7-minute quick-detection
cycle, starting 4 times the first minute, twice the second
minute, and once a minute for the next 5 minutes. If by the
last check it has not detected water, it resumes its cycle (run-
ning 5 seconds every 2-1/2 minutes) until it senses water
again.

NOTICE:

When you plug the pump into the outlet, it will start

and run for 5 seconds. It will then cycle as described above.

If the unit is put in the water and started, interrupting the water
flow into the pump during the 5-second water-sensing run will
cause it to wait 2-1/2 minutes before restarting.

1. The motor is equipped with an automatically resetting

thermal overload protector. If the motor gets too hot, the
overload protector will stop the motor before it is dam-
aged. When the motor has cooled sufficiently, the overload
protector will reset itself and the motor will restart.

NOTICE: 

If the overload protector stops the pump repeated-

ly, disconnect the power from the pump and check it to
find the problem. Low voltage, clogged impeller, too much
back pressure in the discharge hose (as when pumping
through 50’ (15 M) of coiled hose), or extended running of
pump with no load, can all cause overheating.

2. The water being pumped cools the motor, allowing the

pump to run continuously at any depth of water above 1/4".
However, if the motor overload stops the pump, allow it to
cool for one hour before restarting. The motor will not restart
before the overload has cooled. 

LOCKED ROTOR

1. If the pump tries to start and senses that the rotor is locked,

it will shut off, wait 2-1/2 minutes, and try to restart.

2. If the rotor has unlocked, the pump will resume normal

operation. If the rotor is still locked, the pump will shut off
again and wait through another 2-1/2 minute cycle.

3. After 2-1/2 minutes, the pump will again try to start. If the

rotor has unlocked, the pump will resume normal opera-
tion. If the rotor is still locked, the pump will shut off and
will not restart automatically.

4. To restart the pump manually, unplug it and plug it in

again. 

5. If the rotor is still locked, UNPLUG THE PUMP, remove

the base, shield, and screen, and clean out the rotor. 

Risk of dangerous or fatal electrical shock.

Disconnect the pump from the power source before 
disassembling the pump or cleaning out the rotor.

6. See Page 4 for important information about the alignment

of the screen and shield when you reassemble them. Note
that the pump will not operate correctly if these parts are
not correctly installed.

7. Once you have reassembled the pump, reset it on the pool

cover and plug it in again to resume normal operation.

AIRLOCKS

When a pump airlocks, it runs but does not move any water.
An airlock will cause the pump to overheat and fail. This
pump has an anti-airlock hole in the bottom of the pump
body. If you suspect an airlock, unplug the pump, clean out
the anti-airlock hole with a paper clip or piece of wire, and
restart the pump.

NOTICE:

If the outlet of the discharge hose is submerged you

must have a 1/8" hole in the discharge hose to prevent airlock.
This hole must be open to air.

NOTICE:

If you move the pump or the pump airlocks, be sure to

drain the hose before trying to restart the pump.

Summary of Contents for 2115

Page 1: ...tance Call 1 800 468 7867 English Pages 2 5 Installation Fonctionnement Pièces Pour plus de renseignements concernant l utilisation l installation ou l entretien Composer le 1 800 468 7867 Français Pages 6 9 Instalación Operación Piezas Para mayor información sobre el funcionamiento instalación o mantenimiento de la bomba Llame al 1 800 468 7867 Español Paginas 10 13 2007 SIM822 Rev 12 10 07 MODEL...

Page 2: ... application backflow is a problem when the pump stops prevent it by installing a 1 NPT check valve in the pump discharge 4 Power Supply Pump is designed for 115V 60 HZ operation and requires an individual branch circuit of 15 amperes or more capacity It is supplied with a 3 wire cord set with grounding type GFCI protected plug for use in a 3 wire grounded outlet For safety pump should always be e...

Page 3: ...he motor will restart NOTICE If the overload protector stops the pump repeated ly disconnect the power from the pump and check it to find the problem Low voltage clogged impeller too much back pressure in the discharge hose as when pumping through 50 15 M of coiled hose or extended running of pump with no load can all cause overheating 2 The water being pumped cools the motor allowing the pump to ...

Page 4: ... motor fails replace entire pump Not Illustrated SYMPTOM POSSIBLE CAUSE S CORRECTIVE ACTION Pump won t Blown fuse If blown replace with fuse of proper size start or run Low line voltage If voltage under recommended minimum check size of wiring from main switch on property If OK contact power company Defective motor Replace pump Impeller Remove base and screen locate source of binding Pump operates...

Page 5: ... including but not limited to operational failures caused by corrosion rust or other foreign materials in the system or operation at pressures in excess of recommended maximums Requests for service under this warranty shall be made by returning the defective product to the Retail outlet or to SIMER as soon as possi ble after the discovery of any alleged defect SIMER will subsequently take correcti...

Page 6: ... que possible 3 Si en fonction de l utilisation le refoulement représente un problème lorsque la pompe s arrête poser un clapet antire tour de 1 pouce NPT côté refoulement de la pompe 4 Source d alimentation La pompe est conçue pour du 115V et 60HZ et requiert un circuit de dérivation individuel de 15 ampères ou plus Elle est fournie avec un cordon trifilaire et une fiche de type mise à la terre e...

Page 7: ...on répétitive débrancher la pompe et déterminer le problème Une basse tension un impulseur bouché une contre pression trop importante dans le tuyau de refoulement comme pomper de l eau dans un tuyau enroulé ayant jusqu à 50 pieds 15 mètres ou un fonctionnement prolongé à vide de la pompe causera une surchauffe 2 L eau pompée refroidit le moteur ce qui permet à la pompe de fonctionner continuelleme...

Page 8: ...té Le moteur est défectueux Remplacer la pompe Roue hélice Retirer la base et le filtre repérer la source de l obstruction La pompe La tension est faible Appeler la compagnie d électricité fonctionne mais Quelque chose obstrue Nettoyer la roue hélice elle déverse peu la roue hélice ou pas d eau Tuyau d arrosage de petit Utiliser un tuyau souple de 1 pouce ou un tuyau d arrosage de plus grand diamè...

Page 9: ...ausées par la corrosion la rouille ou autre corps étranger dans le système ou à des produits ayant fonctionné à des pressions dépassant la limite maximale recommandée Les demandes de service en vertu de la présente garantie seront faites en retournant le produit défectueux au détaillant ou à SIMER dès la dé couverte de tout défaut allégué SIMER prendra alors les mesures correctives aussi rapidemen...

Page 10: ...roflujo es un problema cuando la bomba se detiene evítelo instalando una válvula de reten ción de 1 NPT en la descarga de la bomba 4 Fuente de alimentación La bomba está diseñada para operar a 115V y 60 Hz y requiere un ramal individual de 15 amperes o más de capacidad Se suministra con un juego de cordón de 3 alambres con enchufe tipo conexión a tierra protegido por un disyuntor para ser utilizad...

Page 11: ...blema Tensiones bajas impulsores bloqueados demasiada presión en la manguera de descarga como en los casos en que se bombea a través de 50 pies 15 metros de manguera enredada o una operación prolongada de la bomba sin carga pueden causar recalentamiento 2 El agua que se bombea enfría el motor lo que permite que la bomba continúe funcionando a cualquier profundidad de agua por encima de 1 4 de pulg...

Page 12: ...a compañía eléctrica Motor defectuoso Reemplace la bomba Impulsor Saque la base y el filtro ubique la fuente de fijación La bomba Bajo voltaje de línea Llame a la compañía de electricidad funcionapero Objeto atascado en el rodete Limpie el impulsor no suministra Manguera de jardín de Use una manguera de jardín de mayor diámetro o un tubo flexible de 1 agua o muy diámetro chico o línea de Deseche e...

Page 13: ... incluyendo pero no limitado a fallas operacionales causadas por corrosión oxidación u otros elementos extraños en el sistema o funcionamiento a presión por encima del máximo recomendado Los pedidos de servicio bajo los términos de esta garantía serán efectuados mediante la devolución del producto defectuoso al Vendedor o a SIMER tan pronto como sea posible después de localizado cualquier supuesto...

Page 14: ...14 For parts or assistance call Simer Customer Service at 1 800 468 7867 1 800 546 7867 ...

Page 15: ...15 For parts or assistance call Simer Customer Service at 1 800 468 7867 1 800 546 7867 ...

Page 16: ......