Test Menu
Startup Bypass
Test Reset
Pellet Feeder
Extractor (exhauster fan)
Fan 1
Fan 2
Pump
Igniter
Photoresist. Calibration On
Photoresist. Calibration Off
Maintenance menu functions list
Table 12
*
This value may be set to 2 only if the 2nd exhauster fan is disabled.
**
The maximum value which can be displayed depends on the set value, controlled by the board.
*** This function is hidden with the 2nd exhauster fan disabled.
To access the selected menu, press key
Set
(key #3); from within the submenu, the item value may be changed by pressing the key
Set
(key #3): The
value shown on the top line starts blinking to let the user being informed that it may be now changed, while “Set” is replaced by “Ok”; the two bottom
keys may be two arrows or may also change in +/-, depending on the displayed data type, and they are used to increase or decrease the item value. By
pressing the button
Ok
(key #3) the new value is confirmed and the display reverts to the previous screen (unflashing).
The display will return to the previous screen without confirming the new value by pressing the
esc
key (key #3). Each submenu item and its value
stay displayed for 60s; after that time the display reverts back to the START screen. By pressing the
On/Off
key (key #5) the display will return to the
START screen without confirming the new value.
The running time reset function deserves a more detailed explanation due to its behaviour and screen, different from those of the other functions.
When the key
Set
(key #3) is pressed, the running time starts blinking; the value shown may be reset by pressing key
Ok
(key #3) (See Fig. 56)
e s c
2 0 0 0
O k
R e s e t
S e r v i c e
T
Running time reset