IT
ENG
63
Function
Value
Time
00 ÷ 23
Minutes
00 ÷ 59
Day
Mo ÷ Su
Day numb.
00 ÷ 31
Month
01 ÷ 12
Year
2010 ÷ 2109
Date and hour menu functions list
Table 7
TIME SCHEDULED ON/OFF OPERATION MODE (“CHRONO” OPERATION)
2.5.4.3
The “chrono” function allows the user to set up 6 different on/off time intervals; each interval may be assigned to one or more day(s) of the week, to
provide the user with a widely flexible and easily configurable weekly scheduling, so to fit any requirement.
The Chrono menu includes a set of data and parameters; on the top line no value is displayed, but only the word
Set
; by pressing the key #3 a submenu
will be acccessed with the same characteristics of the previous one.
The use of this menu is similar to the “Advanced Functions” menu (See §
2.5.4); the available functions are listed in “Table 8 Chrono options list” ,
in the same order as they appear on the display, along with their values.
Function
Value
Enable
On/Off
Reset Chrono
Prog. 1
Prog. 2
Prog. 3
Prog. 4
Prog. 5
Prog. 6
Chrono options list
Table 8
The option “Enable” is used to set active the chrono operation mode, on the basis of the currently defined weekly on/off time pattern; when active, the
relevant string is displayed in the START screen, as described in Table 4.
The option “Reset Chrono” is used to cancel all current settings which will be taken back to the default; a confirmation is required to actually have
the default values loaded.
The scheduling options may be accessed in a new menu level, with a set of data and parameters as detailed in Table 9
Function
Value
P# Enable
On/Off
P# Start
0-23 (15 min steps)
P# Stop
0-23 (15 min steps)
P# Heat. Temp.
40-85 (60 by default)
P# Fire
1-9 (1 by default)
P# Days
Chrono options list
Table 9
To have each daily scheduling set active, both the start and the stop hours must be set in order to define a valid time interval.
The current power the heater must run at and the water temperature data are sent to the main board for each on time interval. This allows the user to
get a high comfort degree within each on time interval. Should two or more schedulings be overlapped, the scheduling pattern with the lower index
will have priority over the other one.
The last item is used to choose the day of the week which will use that daily on/off time pattern.